Updated: Feb 4, 2026

The Multiple Sclerosis Performance Test MSPT: An iPad-Based Disability Assessment Tool
Published on: June 30, 2014
Validation of a precision tremor measurement system for multiple sclerosis
Thushara Perera1, Wee-Lih Lee2, Shivanthan A C Yohanandan3
1The Bionics Institute, East Melbourne, Australia; Department of Medical Bionics, University of Melbourne, Australia.
A new device, TREMBAL, quantifies Multiple Sclerosis (MS) tremor using motion capture. TREMBAL shows comparable reliability to clinical scales, offering a more sensitive measure for MS tremor research and treatment evaluation.
Area of Science:
- Neurology
- Biomedical Engineering
- Rehabilitation Science
Background:
- Multiple Sclerosis (MS) tremor is a significant challenge with limited understanding of its pathophysiology and treatment options.
- Current clinical trials often depend on subjective rating scales, which have limitations in sensitivity and inter-rater reliability.
Purpose of the Study:
- To introduce and validate TREMBAL, a novel instrument employing electromagnetic motion capture technology for objective quantification of MS tremor.
- To compare the performance of TREMBAL against established clinical rating scales in measuring MS tremor.
Main Methods:
- TREMBAL was validated by comparing its measurements to clinical ratings in 310 tremor samples from 13 MS participants performing various hand exercises.
- Regression modeling was utilized to assess the congruence between TREMBAL data and clinical observations.
- Minimum Detectable Change (MDC) and test-retest reliability were calculated for both TREMBAL and clinical ratings.
Main Results:
- The velocity of the index finger measured by TREMBAL demonstrated strong agreement with clinical observations.
- TREMBAL exhibited a marginally lower Minimum Detectable Change (MDC) (84%) compared to clinical ratings (91%).
- TREMBAL achieved higher test-retest reliability (Intra-class correlation: 0.781) than clinical ratings (0.703), and MS tremor was significantly lower in healthy subjects (p=0.002).
Conclusions:
- TREMBAL provides objective and reliable quantification of MS tremor, showing agreement with clinical assessments.
- The novel instrument offers improved sensitivity and reliability over subjective clinical scales, aiding in the evaluation of MS tremor interventions.
- TREMBAL represents a valuable tool for advancing MS tremor research and clinical trial efficacy assessment.