Immediate vs conventional loading of variable-thread tapered implants supporting three- to four-unit fixed partial
Purpose:
To compare the outcome of immediately loaded and one-stage conventionally loaded variable-thread tapered implants in the posterior maxilla.
Materials And Methods:
This study was designed as a split-mouth randomised controlled trial. Twenty-six patients missing teeth bilaterally in the posterior maxilla received three to four implants in each of the posterior sextants. Bone quality was recorded based on Misch criteria (D1-D4) and insertion torque values were measured using a manual wrench. The implants on one side were immediately loaded with a temporary resin fixed partial denture on definitive multi-unit abutments. The implants in the contralateral side received definitive multi-unit abutments according to the one-stage unloaded protocol. Three to 3.5 months following implant placement, the implants were restored with metal-ceramic fixed prostheses. Outcome measures were implant and prosthesis failure rates, complications, and peri-implant bone level changes at 1 year following delivery of the definitive prostheses.
Results:
Two patients dropped out prior to the delivery of definitive prostheses. Four implants supporting a four-unit immediately loaded prosthesis failed in one patient, 3 months following delivery of the definitive prostheses. None of the conventionally loaded implants or prostheses failed. There were no significant differences in the proportions of implant and prosthesis failures (difference = 4.2%; 95% CI -4.2 to 12.6%; P = 0.999). In the immediately loaded group, four early prosthetic complications occurred during the provisionalization phase (three small resin chippings and one prosthetic screw loosening). No other complications were reported. The difference in the rate of complications between the two interventions was not statistically significant (difference = 16.7%; 95% CI -1.2% to 35.6%; P = 0.125). The 1-year peri-implant marginal bone level changes were evaluated in 23 patients (77 immediately loaded and 76 conventionally loaded implants). On average, patients lost 0.42 mm at the immediately loaded and 0.46 mm at the conventionally loaded implants, the difference being statistically not significant (difference = 0.044 mm; 95% CI -0.27 to 0.18 mm; P = 0.701).
Conclusions:
Immediate loading of 3- to 4-unit fixed partial prostheses supported by variable-thread implants in the posterior maxilla can yield good and similar 1-year results to one-stage conventionally loaded implants.
More Related Videos
06:022-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition
Published on: December 26, 2016
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Related Concept Videos
Load-frequency control
Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
Conservation of Mass in Fixed, Nondeforming Control Volume
In the case of a sewer pipe, which can be modeled...
Measurement: Standard Units
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...