Related Experiment Video
Updated: Feb 4, 2026

Rapid Determination of the Thermal Nociceptive Threshold in Diabetic Rats
Published on: May 17, 2012
Difference of Nonlinear Degree between Healthy and Diabetic Rat Erythocyte Fluorescence Spectrum
Abstract:
Diabetes mellitus is one kind of chronic diseases which seriously threaten human health. It is very important to diagnose in the early stage. With the development of diabetes, the structure and function of erythrocyte in the blood will change. So the peak position and peak height of erythrocyte fluorescence spectrum are different. These differences can be used to determine the status of diabetes. In the selection of the difference of spectral signal as the feature vector, the nonlinear degree of fluorescence spectrum can be used as the feature vector. In order to describe the nonlinearity of the fluorescence spectrum signal, the nonlinear degree of the signal is described with the delay vector variance (DVV) method. By using the method of iterative amplitude adjusted Fourier transformation (IAAFT) to generate surrogate data of raw data, the nonlinear characteristic of the raw data is determined by comparing the DVV of the original data and the surrogate data. The variance of the original data is the horizontal coordinates, and the variance of the surrogate data is the longitudinal coordinates, thus the DVV scatter plot is drawn. The DVV scatter plot of healthy rat erythrocyte fluorescence spectrum is almost coincident with its diagonal, which means the nonlinear degree of healthy rat erythrocyte fluorescence spectrum is lower. The DVV scatter plot of diabetic rat erythrocyte fluorescence spectrum deviates from its diagonal, which means the nonlinear degree of healthy rat erythrocyte fluorescence spectrum is higher, also the corresponding amino acid spectrum nonlinearity is deeper. Therefore, it is proposed that the nonlinear difference between the healthy and diabetic fluorescence spectrum can be used as a feature of early diabetes diagnosis.
Related Concept Videos
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
The Electromagnetic Spectrum
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily assigned.
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily...
Degree of Unsaturation
The degree of unsaturation for hydrocarbons is U = (2C + 2 − H) / 2, where C is the number of carbon atoms and H is the number of hydrogen atoms.

