High-throughput Measurement of Dictyostelium discoideum Macropinocytosis by Flow Cytometry

Thomas Williams1, Robert R Kay2

  • 1MRC-Laboratory of Molecular Biology, Cambridge, UK; thomasw@mrc-lmb.cam.ac.uk.

Insights

This study presents a high-throughput method to measure macropinocytosis in Dictyostelium discoideum. The new technique uses fluorescent dextran and flow cytometry for efficient analysis of fluid uptake.

Area of Science:

  • Cell Biology
  • Biochemistry

Background:

  • Macropinocytosis is crucial for cancer cell proliferation, immune responses, and disease spread.
  • Dictyostelium discoideum is a valuable model organism for studying macropinocytosis due to its high uptake rates and conserved molecular machinery.

Purpose of the Study:

  • To develop a high-throughput, labor-efficient method for quantifying macropinocytosis in Dictyostelium discoideum.
  • To adapt existing fluid uptake assays to a 96-well plate format for flow cytometry analysis.

Main Methods:

  • Utilized fluorescent dextran as a tracer for internalized fluid.
  • Employed a 96-well plate format combined with flow cytometry and a high-throughput sampling attachment.
  • Cells were incubated with dextran, washed, treated with sodium azide to halt exocytosis, and then analyzed.

Main Results:

  • Successfully adapted the fluid uptake assay to a high-throughput 96-well plate format.
  • The method allows for efficient, simultaneous comparison of multiple Dictyostelium strains and experimental conditions.
  • The assay can be adapted to measure membrane uptake and phagocytosis.

Conclusions:

  • This optimized method significantly enhances the efficiency and throughput of macropinocytosis research in Dictyostelium discoideum.
  • The technique facilitates parallel comparisons, simplifying time-course studies and inhibitor screenings.
  • This approach provides a robust tool for dissecting the mechanisms of macropinocytosis in a model organism.

Related Concept Videos

Flow Cytometry01:23

Flow Cytometry

The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
16.2K
Gene Flow02:39

Gene Flow

Gene flow is the transfer of genes among populations, resulting from either the dispersal of gametes or from the migration of individuals.
37.9K
Flow Sheet01:17

Flow Sheet

Flowsheets are valuable tools in nursing documentation. They enable healthcare professionals to efficiently record and monitor various patient assessments and measurements in a consolidated format.
Here's a closer look at the examples of flowsheets commonly used by nurses:
Graphic Sheet Documentation:
2.8K
Flow Table Test01:12

Flow Table Test

The flow table test is an established method used to assess the workability of concrete, particularly useful for evaluating highly flowable concrete mixes. This test employs an apparatus that consists of a wooden board topped with a steel plate, collectively weighing 35 pounds. The board is connected to a base via a hinge and measures 27.6 inches on each side.
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
717
Irrotational Flow01:28

Irrotational Flow

Irrotational flow is characterized by fluid motion where particles do not rotate around their axes, resulting in zero vorticity. For a flow to be irrotational, the curl of the velocity field must be zero. This imposes specific conditions on velocity gradients. For instance, to maintain zero rotation about the z-axis, the gradient condition:
1.0K
Turbulent Flow01:24

Turbulent Flow

Turbulent flow is characterized by unpredictable fluctuations in velocity and pressure, which result in a chaotic fluid movement distinct from the orderly patterns of laminar flow. While laminar flow is governed by smooth, parallel layers with minimal mixing, turbulent flow exhibits highly irregular, three-dimensional patterns. This behavior arises due to instabilities in the fluid's velocity profile, and amplifies as the flow velocity increases. Minor disturbances, known as turbulent...
734