Abstract:
Phase contrast magnetic resonance imaging (PC-MRI) is a noninvasive approach that can quantify flow-related parameters such as blood flow. Previous studies have shown that abnormal blood flow may be associated with systemic vascular risk. Thus, PC-MRI can facilitate the translation of data obtained from animal models of cardiovascular diseases to pertinent clinical investigations. In this report, we describe the procedure for measuring blood flow in the common carotid artery (CCA) of rats using cine-gated PC-MRI and discuss relevant analysis methods. This procedure can be performed in a live, anesthetized animal and does not require euthanasia after the procedure. The proposed scanning parameters yield repeatable measurements for blood flow, indicating excellent reproducibility of the results. The PC-MRI procedure described in this article can be used for pharmacological testing, pathophysiological assessment, and cerebral hemodynamics evaluation.
More Related Videos
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
09:11Performing Permanent Distal Middle Cerebral with Common Carotid Artery Occlusion in Aged Rats to Study Cortical Ischemia with Sustained Disability
Published on: February 23, 2016
Related Concept Videos
Magnetic Resonance Imaging
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies IV: Magnetic Resonance Imaging
Atomic Nuclei: Magnetic Resonance
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
Common Ion Effect