Nicole Hättenschwiler1, Marcia Mendes1, Adrian Schwaninger1
1University of Applied Sciences and Arts Northwestern Switzerland, Olten.
Objective:
This study compared the visual inspection performance of airport security officers (screeners) when screening hold baggage with state-of-the-art 3D versus older 2D imaging.
Background:
3D imaging based on computer tomography features better automated detection of explosives and higher baggage throughput than older 2D X-ray imaging technology. Nonetheless, some countries and airports hesitate to implement 3D systems due to their lower image quality and the concern that screeners will need extensive and specific training before they can be allowed to work with 3D imaging.
Method:
Screeners working with 2D imaging (2D screeners) and screeners working with 3D imaging (3D screeners) conducted a simulated hold baggage screening task with both types of imaging. Differences in image quality of the imaging systems were assessed with the standard procedure for 2D imaging.
Results:
Despite lower image quality, screeners' detection performance with 3D imaging was similar to that with 2D imaging. 3D screeners revealed higher detection performance with both types of imaging than 2D screeners.
Conclusion:
Features of 3D imaging systems (3D image rotation and slicing) seem to compensate for lower image quality. Visual inspection competency acquired with one type of imaging seems to transfer to visual inspection with the other type of imaging.
Application:
Replacing older 2D with newer 3D imaging systems can be recommended. 2D screeners do not need extensive and specific training to achieve comparable detection performance with 3D imaging. Current image quality standards for 2D imaging need revision before they can be applied to 3D imaging.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Imaging Studies VII: Vascular Imaging
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Imaging Studies IV: Magnetic Resonance Imaging