Related Experiment Video
Updated: Feb 4, 2026

VirWaTest, A Point-of-Use Method for the Detection of Viruses in Water Samples
Published on: May 11, 2019
Evaluation of different LSC methods for 222Rn determination in waters
Jovana Nikolov1, Ivana Stojković2, Nataša Todorović1
1University of Novi Sad, Faculty of Sciences, Department of Physics, Novi Sad, Serbia.
Abstract:
Monitoring of 222Rn in drinking or surface waters, as well as in groundwater has been performed regularly in connection with geological, hydrogeological and hydrological surveys and health hazard studies. Liquid scintillation counting (LSC) is often preferred analytical method for 222Rn measurements in waters as it allows multiple-sample automatic analysis. LSC method implies mixing of water samples with organic scintillation cocktail, which triggers radon diffusion from the aqueous into an organic phase for which it has a much greater affinity, eliminating the possibility of radon emanation in that manner. The main aim of this paper is calibration of the liquid scintillation counter Qunatulus 1220™ for measuring of radon in water and evaluation of two different methods (one-phase and two-phase) in order to obtain the most suitable LSC technique for radon in water measurement. In this study four different scintillation cocktails were tested: one miscible (Ultima Gold AB) and three immiscible (High Efficiency Mineral Oil Scintillator, Opti-Fluor O and Ultima Gold F). Evaluation of presented methods was based on obtained detection efficiency and achieved Minimal Detectable Activity (MDA) values. Comparison of presented methods, accuracy and precision, as well as different scintillation cocktail's performance, was considered from results of measurements of 226Ra spiked water samples with known activity and environmental samples. LSC results were compared with the results of radon in water measurement obtained by alpha spectrometer RAD7. Calibration was done as a dependence of calibration factor (CF) from Pulse Shape Analysis (PSA). According to the obtained results, with proper adjustment of calibration parameters, both methods could be used for radon in water measurements. The obtained MDA values for all four scintillation cocktails are very low, less than 0.1 Bq l-1 for measuring time of 300 min.
More Related Videos
Related Concept Videos
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
Dose Size and Dosing Frequency: Determination Methods
Dosage Interval and Administration Route: Determination Methods
The Water Cycle
Water and Mineral Acquisition

