The Effect of Artificial Tear Preparations with Three Different Ingredients on Contrast Sensitivity in Patients with
1Fatih Sultan Mehmet Education and Training Hospital, Ophthalmology Clinics, Bostancı, Istanbul, Turkey.
Abstract:
This study was conducted to investigate the effects of Artificial Tear Preparations (ATP) with three different ingredients on contrast sensitivity in patients with dry eye syndrome. Contrast sensitivity measurements were obtained before and 5, 15, 30, 60, and 90 minutes after administering three different ATPs, containing dextran 70, hydroxypropyl methylcellulose (ATP-1), polyvinyl alcohol-povidone (ATP-2) and carbomer (ATP-3) to one eye of 20 patients with dry eye syndrome, who had been divided to three groups. Contrast sensitivity measurements were obtained at 1.5, 3, 6, 12, and 18 spatial frequencies (cpd). Compared with the baseline measurements, ATP-1 provided a significant increase of 1.5 and 3 cpd at the 15th minute, 12 cpd at the 60th minute, and 18 cpd at the 30th minute, ATP-2 significantly increased contrast sensitivity compared with the baseline at the 15th, 30th, 60th, and 90th minute measurements, recorded as 1.5, 3, 12, and 18 cpd, and ATP-3 provided significant increases of 18 cpd at 60th and 90th minute measurements compared with the baseline. In conclusion, while ATP-2 increased the majority of contrast sensitivity measurements both at early, mid, and late terms, the ATP-1 and ATP-3 were found to be effective on mid-term and late-term contrast sensitivity measurements, respectively.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Dry Friction
To illustrate this concept, imagine a wooden crate resting on a rough, non-uniform horizontal surface. When an external force is applied to...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Natural and Artificial Concepts
Characteristics of Dry Friction
Before the wheelbarrow starts moving, the static frictional force acts tangentially to the contact surface, opposing the force that is about to induce the motion. This frictional force prevents the...
Nephrotic Syndrome I : Introduction