Real-time surveillance of left atrial appendage thrombus during contrast computed tomography imaging for catheter

Tetsuma Kawaji1, Hitomi Numamoto2, Shintaro Yamagami3

  • 1Department of Cardiology, Mitsubishi Kyoto Hospital, 1 Katsura Gosho-cho, Nishikyo-ku, Kyoto, 615-8087, Japan. kawaji@kuhp.kyoto-u.ac.jp.

Insights

A new real-time approach using left atrial contrast computed tomography (LA-CT) significantly improves the detection of left atrial appendage filling defects. This method enhances diagnostic accuracy, potentially offering superiority over transesophageal echocardiography for excluding left atrial appendage thrombus.

Area of Science:

  • Cardiology
  • Radiology
  • Medical Imaging

Background:

  • Left atrial contrast computed tomography (LA-CT) and transesophageal echocardiography (TEE) are used to detect left atrial appendage (LAA) thrombus.
  • Incomplete LAA filling can limit the diagnostic accuracy of LA-CT.
  • Real-time surveillance of LAA filling defects (FD) may improve LA-CT utility.

Purpose of the Study:

  • To validate the utility of a real-time approach for LA-CT with real-time surveillance of LAA-FD.
  • To compare the diagnostic accuracy of a novel LA-CT protocol with real-time surveillance against a conventional protocol.

Main Methods:

  • A consecutive cohort of 894 patients undergoing LA-CT for catheter ablation was analyzed.
  • Patients were divided into a conventional protocol group (N=474) and a novel protocol group with real-time LAA-FD surveillance and optional delayed scanning (N=420).
  • LAA-FD severity was graded: Grade-0 (complete filling), Grade-1 (incomplete filling), and Grade-2 (complete defect).

Main Results:

  • The novel protocol significantly reduced the prevalence of LAA-FD (Grade-1 and Grade-2) compared to the conventional protocol (1.0% vs. 28.5%).
  • No Grade-2 FD was observed in the novel protocol group after additional scanning.
  • The novel approach improved diagnostic accuracy, correctly identifying LAA status in cases where TEE suggested thrombus but LA-CT with real-time surveillance showed an intact LAA.

Conclusions:

  • Real-time surveillance during LA-CT enhances the detection and characterization of LAA-FD.
  • This novel LA-CT approach demonstrates improved diagnostic accuracy for excluding LAA thrombus compared to conventional methods.
  • LA-CT with real-time surveillance shows potential superiority over TEE in excluding LAA thrombus.

Related Concept Videos

Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
375
Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
8.4K
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
591
Design Example: Traverse Angle Computations01:25

Design Example: Traverse Angle Computations

Traverse angle computations are a critical component of surveying, used to compute the internal angles within a closed traverse. A traverse consists of a series of connected lines forming a closed loop, often used for land boundary delineation or mapping. Calculating the internal angles ensures accuracy in the traverse geometry and is essential for checking survey data integrity.The process begins with known azimuths and bearings of the traverse sides. Internal angles at each vertex are...
342
Area Computation by the Alternative Coordinate Method01:24

Area Computation by the Alternative Coordinate Method

The alternative coordinate method, also known as the Shoelace Formula, is a technique for determining the area of a traverse using Cartesian coordinates. This method relies on the sequential arrangement of x and y coordinates for each point of the shape, ensuring accuracy and ease of application.In this approach, each corner's x and y coordinates are listed as fractions, with the x-coordinate as the numerator and the y-coordinate as the denominator. These coordinates are arranged sequentially...
639
Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
7.4K