Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Minimally Invasive Transforaminal Interbody Fusion With Robotically Assisted Bilateral Pedicle Screw Fixation:
Jakub Godzik1, Corey T Walker1, Nicholas Theodore2
1Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona.
Abstract:
Minimally invasive surgery (MIS) techniques may enable faster patient recovery and reduce the incidence of postoperative infections. Image-guided approaches to spinal instrumentation and interbody fusion have gained popularity in MIS, reducing radiation exposure and improving screw placement accuracy. Use of a novel computed tomography (CT) navigation-based robotic arm provides for live image-guided surgery, with the potential for augmenting existing MIS approaches and improving the accuracy of instrumentation placement. We report on the surgical technique of MIS transforaminal lumbar interbody fusion (TLIF) performed with the assistance of a new robotic device (ExcelsiusGPS, Globus Medical Inc, Audubon, Pennsylvania) and intraoperative CT guidance in a patient with single-level lumbar spondylolisthesis. The patient gave written informed consent before treatment. Institutional review board approval was deemed unnecessary. The patient was positioned prone on the operating room table, and an intraoperative CT was obtained with stereotactic arrays placed bilaterally in the posterior superior iliac spine. Screw trajectories were planned using the ExcelsiusGPS software and placed percutaneously with the robotic arm without using a Kirschner wire. Interbody placement was performed via an expandable retractor after muscle dilation. Screw placement accuracy was determined with postoperative CT, which demonstrated good screw positioning without breach. The patient recovered well and was discharged home without complications. The combined use of the new robotic device and intraoperative CT enables accurate and safe fixation for the treatment of symptomatic lumbar spondylolisthesis. The operative video demonstrates the technical nuances of positioning, stereotactic marker placement, work flow, and screw placement. Used with permission from Barrow Neurological Institute, Phoenix, Arizona.
Related Concept Videos
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...