Related Experiment Video
Updated: Feb 4, 2026

Experimental Model of Ligature-Induced Peri-Implantitis in Mice
Published on: May 17, 2024
Titanium as a modifier of the peri-implant microbiome structure
Diane Daubert1, Alexander Pozhitkov2, Jeffrey McLean3,4
1Department of Periodontics, Clinical and Periodontal Research Laboratory, University of Washington, Seattle, WA (Washington), USA.
Background:
Recent data support the implication of accelerated titanium dissolution products in peri-implantitis. It is unknown whether these dissolution products have an effect on the peri-implant microbiome, the target of existing peri-implantitis therapies.
Purpose:
This study assessed the relationship between the peri-implant microbiome, dissolved titanium levels, and peri-implantitis.
Materials And Methods:
Clinical, microbiome, and titanium data were collected from a periodontal population having implants in function for 10 years. Clinical examinations were performed, and submucosal plaque samples were collected from the deepest site per implant. An aliquot of the sample was used for 16S rRNA gene sequencing, with the remainder analyzed for titanium quantity using mass spectrometry. Sequences were clustered into taxonomic units at 97% minimum sequence similarity using the QIIME pipeline approach.
Results:
Fifteen implants were assessed. According to established case definitions, six had a diagnosis of peri-implantitis; nine were healthy. The genera Streptococcus, Prevotella and Haemophilus characterized peri-implant health. Peri-implantitis was associated with a marked increase in Veillonella. Quantities of dissolved titanium were identified in 40% of sites. Titanium presence was associated with peri-implant disease status (P = .02) and correlated to the first principal component of the microbiome (rho = 0.552) and its alpha-diversity (rho = -0.496). Canonical correlation analyses found that titanium levels, but not health or disease status of the implant, were significantly associated with the microbiota composition (P = .045).
Conclusions:
These findings suggest an association between titanium dissolution products and peri-implantitis and support a role for these products in modifying the peri-implant microbiome structure and diversity.
More Related Videos
06:06Adjunctive Diode Laser Therapy and Probiotic Lactobacillus Therapy in the Treatment of Periodontitis and Peri-Implant Disease
Published on: May 9, 2022
07:28Imaging Cell Viability on Non-transparent Scaffolds — Using the Example of a Novel Knitted Titanium Implant
Published on: September 7, 2016
Related Concept Videos
Structure of Lipids
Modified Boxplots
However, the box plot does not tell the reader about outliers - values that lie far from the center of the data. We can modify the standard box and whisker plot to identify the outliers and visualize the actual spread of the data in a sample.
Initially, we calculate the adjusted...
Structures of Solids
Structural Isomerism
Isomers are different chemical species that have the same chemical formula. Structural isomerism of coordination compounds can be divided into two subcategories, the linkage isomers and coordination-sphere isomers.
Linkage isomers occur when the coordination compound contains a ligand that can bind to the transition metal center through two different atoms. For example, the CN− ligand can bind through the carbon atom or through the nitrogen atom. Similarly, SCN− can...
Viral Structure
Antibody Structure
Antibodies, also known as immunoglobulins (Ig), are essential players of the adaptive immune system. These antigen-binding proteins are produced by B cells and make up 20 percent of the total blood plasma by weight. In mammals, antibodies fall into five different classes, which each elicits a different biological response upon antigen binding.
The Y-Shaped Structure of Antibodies Consists of Four Polypeptide Chains
Antibodies consist of four polypeptide chains: two identical heavy...