Alternating Magnetic Field-Responsive Hybrid Gelatin Microgels for Controlled Drug Release
Published on: February 13, 2016
Controlled Release of Doxycycline by Magnetized Microporous MIL53(Fe); Focus on Magnetization and Drug Loading
Shakiba Naeimi1, Hossein Faghihian1
1Department of Chemistry, Shahreza Branch, Islamic Azad University, Shahreza, Iran P.O. Box 311-86145, Shahreza, Iran.
Background:
In this research, MIL-53(Fe) was magnetized and the performance of the magnetized material as a drug delivery system for doxycycline was studied.
Objectives:
The experiments were designed to load the magnetic delivery compounds with different amount of the drug.
Methods:
The in vitro release rate of doxycycline from magnetic MIL-53(Fe) with different drug content into saline buffered fluid (SBF, pH=7.4) and phosphate buffered saline (PBS, pH=3) was then studied.
Results:
The results showed that the releasing process of the drug in PBS media achieved the equilibration within 48h with 98% of releasing efficiency, while the releasing process in SBF media (pH=7.4) was slower and the equilibrium was established within 264 h with the releasing efficiency of 95%. The amount of the released doxycycline from the samples with different drug content was measured at various time intervals.
Conclusion:
It was concluded that in PBS media after 75 h, 85, 95 and 98% of loaded doxycycline released, respectively, from the sample containing 22, 32 and 35% of the drug. In SBF media, the release was slower and after 350 h, 82, 91 and 95% of loaded doxycycline released from the samples, respectively, containing 22, 32 and 35 % of the drug. The results of this study indicated that by use of drugreleasing profile and selecting appropriate carrier dose, the released amount of the drug into the patient body can be controlled.
More Related Videos
Related Concept Videos
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Magnetism
An individual magnetic pole cannot be isolated. No matter how small, every piece of a magnet contains a north pole and a south...
Load-frequency control
Magnetic Flux
Suppose a surface is divided into elements of area dA. For each element, the component of the magnetic field that is normal to the...
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Magnetic Declination