Modified Ritgen Maneuver in Perineal Protection - Sixty-Year Experience

Dubravko Habek1, Ana Tikvica Luetić1, Ingrid Marton1

  • 1University Department of Obstetrics and Gynecology, Sveti Duh University Hospital, Croatian Catholic University, Zagreb, Croatia.

Acta Clinica Croatica
|September 27, 2018
PubMed

The aim is to present the 60-year experience in modified Ritgen maneuver according to perineal injuries. This retrospective clinical observational study (1950-2010) analyzed the impact of modified Ritgen maneuver delivery technique (controlled fetal head deflexion with left hand and synchronous reduction of perineal strain with extended right hand thumb along the right side of the vulva and perineum without pushing) on peripartum perineal tears at the Maternity Ward, Bjelovar General Hospital in Bjelovar, Croatia, divided into five-year intervals. The rate of perineal tear in general was less than 5% until 2000. The rate of perineal tear grade I was very low until 1995, then increased to 8.6% in 2010, yet never exceeding 10%. The rate of perineal tear grade II never exceeded 2%, whereas perineal tear grade III was a sporadic event never exceeding 0.4% of the study material with a single case of grade IV tear. The rate of intact perineum in vaginal deliveries without episiotomy ranged from 96.2% to 100% in the 1950-1960 period, with a decrease to 46% in 2010. The study revealed the modification of Ritgen maneuver described to have resulted in significant re-duction of all grades of perineal tear over decades.

Related Concept Videos

Protection of Alcohols02:31

Protection of Alcohols

This lesson delves into the concept of protection and deprotection of a functional group fundamental to synthetic organic chemistry. These phenomena are explained in the context of aliphatic and aromatic alcohols.
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
8.1K
Zones of Protection01:16

Zones of Protection

In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
808
Radial System Protection01:23

Radial System Protection

Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
445
Protecting Self-Esteem01:27

Protecting Self-Esteem

Self-esteem, a central component of psychological well-being, is actively maintained through various cognitive and behavioral strategies. Individuals employ specific mechanisms to preserve a positive self-concept and mitigate threats to their self-worth, particularly in contexts involving social evaluation or personal feedback. Four primary techniques are commonly used to sustain self-esteem.Manipulating AppraisalsOne prominent strategy involves manipulating appraisals from others. Individuals...
213
What is an Experiment?01:12

What is an Experiment?

An experiment is a planned activity carried out under controlled conditions. The purpose of an experiment is to investigate the relationship between two variables. When one variable causes change in another, we call the first variable the explanatory or independent variable. The affected variable is called the response or dependent variable. In a randomized experiment, the researcher manipulates values of the explanatory variable and measures the resulting changes in the response variable. The...
18.6K
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
457