Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
The ACURATE neo transcatheter aortic valve system
Tawfiq Choudhury1, Amir Solomonica1, Rodrigo Bagur1,2
1a London Health Sciences Centre , London , Canada.
Transcatheter aortic valve implantation (TAVI) using the ACURATE neo device shows promising results for severe aortic stenosis, with low mortality and complication rates. Further randomized trials are needed to confirm long-term durability and compare it with other TAVI valves.
Area of Science:
- Cardiovascular Medicine
- Interventional Cardiology
- Medical Device Technology
Background:
- Severe symptomatic aortic stenosis requires intervention, with transcatheter aortic valve implantation (TAVI) emerging as a key treatment modality.
- The ACURATE neo is a second-generation, self-expanding TAVI system featuring a supra-annular design and unique 'top-down' deployment.
- This device aims to minimize left ventricular outflow-tract protrusion, potentially reducing conduction abnormalities.
Purpose of the Study:
- To review the characteristics and clinical outcomes of the ACURATE neo TAVI system.
- To assess the safety and efficacy of the ACURATE neo valve based on available observational data.
- To identify areas for future research and device development in TAVI.
Main Methods:
- Information was compiled from published manuscripts retrieved via MEDLINE searches.
- Conference presentations and trial data were also incorporated into the review.
- Expert commentary was provided based on the synthesized evidence.
Main Results:
- Observational data indicate low rates of all-cause mortality with the ACURATE neo TAVI.
- The device is associated with low rates of paravalvular leak and permanent pacemaker requirement.
- The transfemoral and transapical delivery systems facilitate a 'top-down' deployment.
Conclusions:
- TAVI with the ACURATE neo demonstrates favorable short-term outcomes in observational studies.
- Randomized comparative data and long-term durability studies are pending.
- Ongoing device modifications are expected to further enhance TAVI performance and reduce paravalvular leak.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Aortic Regurgitation I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Aortic Regurgitation III: Medical Management