Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
Published on: September 6, 2024
Outracing Lung Signal Decay - Potential of Ultrashort Echo Time MRI
Mark Oliver Wielpütz1,2,3, Simon M F Triphan1,2,3, Yoshiharu Ohno4
1Department of Diagnostic and Interventional Radiology, Subdivision of Pulmonary Imaging, University Hospital of Heidelberg, Heidelberg, Germany.
Background:
Magnetic resonance imaging (MRI) of the pulmonary parenchyma is generally hampered by multiple challenges related to patient respiratory- and circulation-related motion, low proton density and extremely fast signal decay due to the structure of the lungs evolved for gas exchange.
Methods:
Systematic literature database research as well as annual participation in conferences dedicated to pulmonary MRI for more than the past 20 years by at least one member of the author team.
Results And Conclusion:
The problem of motion has been addressed in the past by developments such as triggering, gating and parallel imaging. The second problem has, in part, turned out to be an advantage in those diseases that lead to an increase in lung substance and thus an increase in signal relative to the background. To reduce signal decay, ultrashort echo time (UTE) methods were developed to minimize the time between excitation and readout. Having been postulated a while ago, improved hardware and software now open up the possibility of achieving echo times shorter than 200 µs, increasing lung signal significantly by forestalling signal decay and more effectively using the few protons available. Such UTE techniques may not only improve structural imaging of the lung but also enhance functional imaging, including ventilation and perfusion imaging as well as quantitative parameter mapping. Because of accelerating progress in this field of lung MRI, the review at hand seeks to introduce some technical properties as well as to summarize the growing data from applications in humans and disease, which promise that UTE MRI will play an important role in the morphological and functional assessment of the lung in the near future.
Key Points:
· Ultrashort echo time MRI is technically feasible with state-of-the-art scanner hardware.. · UTE MRI allows for CT-like image quality for structural lung imaging.. · Preliminary studies show improvements over conventional morphological imaging in lung cancer and airways diseases.. · UTE may improve sensitivity for functional processes like perfusion and tissue characterization..
Citation Format:
· Wielpütz MO, Triphan SM, Ohno Y et al. Outracing Lung Signal Decay - Potential of Ultrashort Echo Time MRI. Fortschr Röntgenstr 2019; 191: 415 - 423.
Related Concept Videos
Resting Potential Decay
At rest, the K+ is the main ion that moves across the membrane...
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Radioactive Decay and Radiometric Dating
Basic Continuous Time Signals
The unit step function, denoted u(t), is zero for negative time values and one for positive time values, exhibiting a discontinuity at t=0. This function often represents abrupt changes, such as the step voltage introduced when turning a car's...
Basic Discrete Time Signals
The unit impulse or sample sequence is mathematically expressed as zero for all n values except at n=0, where it is one. The unit impulse sequence, denoted by δ(n), is the first difference of the unit step sequence, while the unit step sequence u(n) is the...
Sampling Continuous Time Signal
In the...