Anaesthetic management during intracranial mechanical thrombectomy: systematic review and meta-analysis of current
Guillaume Gravel1, Grégoire Boulouis1, Wagih Benhassen1
1INSERM UMR 894, Department of Neuroradiology, Centre Hospitalier Sainte Anne, Université Paris-Descartes, Paris, France.
Objective:
Our aim was to compare the clinical outcome of patients with ischaemic stroke with anterior large vessel occlusion treated with stent retrievers and/or contact aspiration mechanical thrombectomy (MT) under general anaesthesia (GA) or conscious sedation non-GA through a systematic review and meta-analysis.
Methods:
The literature was searched using PubMed, Embase and Cochrane databases to identify studies reporting on anaesthesia and MT. Using fixed or random weighted effect, we evaluated the following outcomes: 3-month mortality, modified Rankin Score (mRs) 0-2, recanalisation success (thrombolysis in cerebral infarction (TICI) ≥2b) and symptomatic intracerebral haemorrhagic (sICH) transformation.
Results:
We identified seven cohorts (including three dedicated randomised controlled trials), totalling 1929 patients (932 with GA). Over the entire sample, mortality, mRs 0-2, TICI≥2b and sICH rates were, respectively 17.5% (99% CI 9.7% to 29.6%; Q-value: 60.1; I2: 93%, 1717 patients), 42.1% (99% CI 33.3% to 51.7%; Q-value: 41.3; I2: 87.9%), 82.9% (99% CI 74.0% to 89.1%; Q-value: 20.7; I2: 80.6%, 1006 patients) and 5.5% (99% CI 2.8% to 10.8%; Q-value: 18.6; I2: 78.5%). MT performed in non-GA patients was associated with better 3-month functional outcome (pooled OR, 1.35; 99% CI 1.04 to 1.76; Q-value: 24.0; I2: 9.2%, 1845 patients) and lower 3-month mortality rate (pooled OR, 0.70; 99% CI 0.49 to 0.98; Q-value: 1.4; I2: 0%, 1717 patients; fixed weighted effect model) compared with GA. MT performed under conscious sedation non-GA had significantly shorter onset-to-recanalisation and onset-to-groin delay compared with GA, and recanalisation success and sICH were similar.
Conclusion:
Non-GA during MT for anterior acute ischaemic stroke with current-generation stent retriever/aspiration devices is associated with better 3-month functional outcome and lower mortality rates. These unadjusted estimates are subject to biases and should be interpreted with caution.
More Related Videos
08:36Author Spotlight: Evaluating the Adjuvant Efficacy and Safety of Angong Niuhuang Pill in Viral Encephalitis Treatment
Published on: April 19, 2024
10:23Author Spotlight: A Machine-Vision Approach to Transmission Electron Microscopy Workflows, Results Analysis and Data Management
Published on: June 23, 2023
Related Concept Videos
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Analysis of Population Pharmacokinetic Data
Random and Systematic Errors
Directing Effect of Substituents: meta-Directing Groups