Foetal Doppler Parameters as a Prognostic Marker Before Induction of Labour

Peter Widschwendter1, Krisztian Lato1, Thomas W P Friedl1

  • 1Frauenklinik, Klinikum der Universität Ulm, Ulm, Germany.

Introduction The value of foetal Doppler ultrasonography before induction of labour for prognostic assessment of the duration of labour and foetal outcome is presented. Patients and Methods Doppler ultrasound of the foetal middle cerebral artery (MCA) and of the umbilical artery (UA) was performed in addition to evaluation of the Bishop score in 49 women around the expected date of confinement (38 + 0 - 42 + 0 weeks of gestation) prior to planned pharmacological induction of labour. These parameters were studied using non-parametric statistical methods for associations with the duration of induction until delivery, the mode of delivery and foetal outcome. Results The resistance index (RI) of the MCA (rs = 0.547, p < 0.001), but not the RI of the UA (rs = - 0.055, p = 0.707) correlated positively with the duration of induction. Moreover, a negative correlation was found between the RI of the UA and the baby's arterial cord pH at birth (rs = - 0.287, p = 0.046). No differences in the RI of MCA or UA were found between babies born vaginally and those delivered by secondary section. Conclusion The present data show that Doppler measurement of the foetal MCA and UA before pharmacological induction of labour at term can be a further parameter for prognostic estimation of the duration and success of induction and of foetal outcome in addition to the established Bishop score.

Related Concept Videos

Doppler Effect - I00:56

Doppler Effect - I

The Doppler effect and Doppler shift were named after the Austrian physicist and mathematician Christian Johann Doppler in 1842, who conducted experiments with both moving sources and moving observers. Consider an observer standing on a street corner, observing an ambulance with a siren sound passing by at a constant speed. The observer experiences two characteristic changes in the sound of the siren. Initially, the sound increases in loudness as the ambulance approaches and decreases in...
6.4K
Doppler Effect - II01:05

Doppler Effect - II

The Doppler effect has several practical, real-world applications. For instance, meteorologists use Doppler radars to interpret weather events based on the Doppler effect. Typically, a transmitter emits radio waves at a specific frequency toward the sky from a weather station. The radio waves bounce off the clouds and precipitation and travel back to the weather station. The radio frequency of the waves reflected back to the station appears to decrease if the clouds or precipitation are moving...
4.8K
Wave Parameters01:10

Wave Parameters

The simplest mechanical waves are associated with simple harmonic motion and repeat themselves for several cycles. These simple harmonic waves can be modeled using a combination of sine and cosine functions. Consider a simplified surface water wave that moves across the water's surface. Unlike complex ocean waves, in surface water waves, water moves vertically, oscillating up and down, whereas the disturbance of the wave moves horizontally through the medium. If a seagull is floating on the...
9.4K
Induction01:16

Induction

An emf is induced when the magnetic field in a coil is changed by pushing a bar magnet into or out of the coil. emfs of opposite signs are produced by motion in opposite directions, and the directions of emfs are also reversed by reversing poles. The same results are produced if the coil is moved rather than the magnet—it is the relative motion that is important. The faster the motion, the greater the emf. Additionally, there is no emf when the magnet is stationary relative to the coil.
A...
5.7K
Self-Inductance01:24

Self-Inductance

Mutual inductance arises when a current in one circuit produces a changing magnetic field that induces an emf in another circuit. On the other hand, self-inductance arises when the current passing through the circuit changes, creating a changing magnetic flux, resulting in inductance in the same circuit.
Consider a circuit connected to an AC source. As the current varies with time, the magnetic flux through the circuit correspondingly changes. Faraday's law tells us that an emf would...
3.1K
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
2.5K