Related Experiment Video
Updated: Feb 4, 2026

In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
Left Ventricular Assist Device Inflow Cannula Position May Contribute to the Development of HeartMate II Left
Jay K Bhama1, Aditya Bansal2,3
1Department of Surgery, University of Iowa Health Care, Iowa City, IA.
Background:
Pump thrombosis (PT) is a dreaded complication after left ventricular assist device (LVAD) implantation. Problems with inflow cannula (IC) position may precipitate thrombus development. We sought to determine if IC position contributes to the development of PT.
Methods:
We conducted a retrospective review of 76 HeartMate II LVAD implants. The angle of the IC (AIC) to the horizontal plane was measured on chest x-rays. Patients who developed PT (PT group) were compared to the remaining patients (control group).
Results:
The mean age at implantation was 56 ± 14 years, and 82% of the patients were male. Ten patients (13%) developed PT. Six (60%) required device exchange, and 4 (40%) were managed with anticoagulation and/or thrombolysis. The median AIC for all patients at implantation was 59° (range, 38°-98°; 25th-75th interquartile range, 50°-75°). In the PT group, the median AIC was larger at the time of PT diagnosis compared to implantation (70° vs 60°, P = 0.005). In the control group, the median AIC was also larger at follow-up compared to implantation (61° vs 58°, P < 0.001) although to a lesser degree than in the PT group. No difference was seen in the median AIC between the PT group and the control group at implantation (60° vs 58°, respectively; P = 0.668) or at follow-up (70° vs 61°, respectively; P = 0.309). However, the median AIC at follow-up in the PT group was significantly larger than the median AIC at implantation in the control group (70° vs 58°, respectively; P = 0.014).
Conclusion:
The HeartMate II LVAD IC position contributes to the development of PT. Regular monitoring of cannula position may help identify patients at risk for this problem.
Related Concept Videos
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...
Cardiac Catheterization III: Left Heart Catheterization
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Matrix-Assisted Laser Desorption Ionization (MALDI)