Is echocardiographic epicardial fat thickness increased in patients with coronary artery disease? A systematic review and meta-analysis
Related Experiment Video
Updated: Feb 4, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Mohammad Ali Ansari1, Mohsen Mohebati2,3, Farid Poursadegh4
1Atherosclerosis Prevention Research Center, Department of Cardiovascular Diseases, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
Background:
The relation of epicardial fat thickness (EFT) to coronary artery disease (CAD) has recently been reported in multiple studies. Echocardiography is a safe and relatively inexpensive and accessible approach to assess regional EFT, which can be performed easily in many centers.
Objective:
To determine the association between echocardiographic EFT and the presence or the absence of CAD.
Methods:
This was a systematic review and meta-analysis conducted on literature available in electronic databases up to March 2018. The articles measuring EFT by echocardiography in the right ventricular (RV) free wall were included in the study. The quality of the enrolled items was assessed using the Methodological Index for Non-Randomized Studies (MINORS) checklist. The analyses were performed using the Comprehensive Meta-Analysis version 2 software. Cochran's Q test and I2 index were used to evaluate heterogeneity.
Results:
This meta-analysis was performed on 13 studies involving 2,436 patients (1,622 with CAD, and 814 without CAD). The maximum EFT reported by echocardiography was 12.9±2.7 mm in the CAD group and 8.4±2.5 mm in the non-CAD group. The minimum EFT reported by echocardiography was 2.2±1.8 mm in the CAD group and 1.8±1.4 mm in the non-CAD group. The heterogeneity was found among the researched studies (I2=91.8%, p=0.000, Q-value=146.43, df [Q] =12) using the random effect model. The patients with CAD had a significantly higher echocardiographic EFT than those without CAD (SMD=1.03, 95% CI= 0.70-1.37, p=0.000).
Conclusion:
According to the findings of this meta-analysis, the echocardiographic EFT in the subjects with CAD was significantly higher than that of those without CAD. The measurement of echocardiographic EFT seems to be an acceptable strategy for risk stratification of heart diseases considering ease of use, cost-effectiveness and non-exposure characteristics, compared to other imaging interventions.
More Related Videos
07:55Echocardiographic Characterization of Left Ventricular Structure, Function, and Coronary Flow in Neonate Mice
Published on: April 7, 2022
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Coronary Artery Disease I: Introduction
Coronary Artery Disease II: Pathophysiology
Coronary Artery Disease V: Interprofessional Care
Coronary Artery Disease III: Clinical Manifestations
Coronary Artery Disease IV: Preventive Measures
Peripheral Artery Disease I: Introduction