Related Experiment Video
Updated: Feb 4, 2026

One-day Workflow Scheme for Bacterial Pathogen Detection and Antimicrobial Resistance Testing from Blood Cultures
Published on: July 9, 2012
A novel method to detect bacterial resistance to disinfectants
Xiao-Feng He1, Hui-Jie Zhang2, Jin-Gui Cao1
1Department of Infection Control, Air Force General Hospital, Beijing 100142, China.
Abstract:
In clinical practice, the important hygienic prevention of bacterial pathogen spread is disinfection of potentially contaminated area. Benzalkonium bromide and chlorhexidine acetate are commonly used disinfectants with a broad spectrum of anti-microbial effect. It is vital to inhibit the spread of pathogen in hospital. However, a large number of pathogens with the decreased antiseptic susceptibility have been isolated from clinical samples which showed an increased minimal inhibitory concentration (MIC) against those antiseptics. These resistant pathogens are the major causes for nosocomial cross-infections in hospital. The present study demonstrated the utility of Oxford plate assay system in determining the potential disinfectant resistance of bacteria. The microbiological assay is based on the inhibitory effect of tested disinfectants upon the strains of Staphylococcus aureus and Escherichia coli. Statistical analysis of the bioassay results indicated the linear correlation (r = 0.87-0.99, P < 0.01) between the diameter of growth inhibition zone and the log dosage of the tested disinfectants. Moreover, comparison of inhibitory efficacy of benzalkonium bromide upon 29 S. aureus strains isolated from clinical samples by both Oxford plate method and broth dilution method showed that the diameter of growth inhibition zone has significantly negative correlation with the minimal inhibitory concentration (MIC) (r = -0.574, P < 0.001). These results suggest that the Oxford plate is a simple and time-saving method in detecting potential clinical disinfectant resistance and its usefulness for routine surveillance of pathogenic resistance to disinfectants warrants further investigation.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Bacterial Transformation
Griffith made an unexpected discovery when he killed the pathogenic strain and mixed its remains with the live, non-pathogenic strain. Not only did the mixture kill host mice, but it also contained living pathogenic bacteria that...
Bacterial Signaling
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Resistivity
Resistance