Transcatheter Aortic Valve Replacement With a Repositionable Self-Expanding Prosthesis: The PORTICO-I Trial 1-Year
Lars Søndergaard1, Josep Rodés-Cabau2, Axel Hans-Peter Linke3
1Department of Cardiology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark.
Background:
The new self-expanding, repositionable transcatheter heart valve (THV) system was designed for treatment of severe, symptomatic aortic stenosis in patients with high surgical risk.
Objectives:
The purpose of this study was to report 1-year outcomes of transcatheter aortic valve replacement with the new THV system.
Methods:
This ongoing, international, multicenter study evaluated patients with severe, symptomatic aortic stenosis implanted with the THV via transfemoral access and follow-up at 30 days, 1 year, and annually through 5 years. The primary endpoint is all-cause mortality at 1 year; secondary endpoints include clinical outcomes and echocardiographic measurements, both adjudicated.
Results:
A total of 941 patients (82.4 ± 5.9 years; 65.7% female; Society of Thoracic Surgeons Predicted Risk of Operative Mortality score: 5.8%) were enrolled and underwent an implant at 61 sites in Europe, Australia, and Canada. At 1 year, Kaplan-Meier estimates for all-cause mortality, cardiovascular mortality, disabling stroke rates, and myocardial infarction were 12.1%, 6.6%, 2.2%, and 2.5%, respectively. Mean aortic transvalvular gradient and aortic valve area were 8.66 mm Hg and 1.75 cm2, respectively. Paravalvular leakage was moderate or higher in 2.6% of patients with no severe leakage. New pacemaker rates were 18.7% and 21.3% for pacemaker naïve patients at 30 days and 1 year, respectively. Functional class, exercise capacity, and quality of life improved significantly from baseline to 1 year.
Conclusions:
Transcatheter aortic valve replacement with the new THV in patients who are at increased surgical risk is associated with low 1-year mortality and stroke rates. Favorable hemodynamic results at 1 year are observed with low transvalvular pressure gradient and incidence of significant paravalvular leakage. (5 Year Observation of Patients With PORTICO Valves [PORTICO-I]; NCT01802788).
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Related Concept Videos
Clinical Trials: Overview
Trial and Error and Algorithm
Clinical Trials
There are four phases in a clinical trial. A phase one...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...