Related Experiment Video
Updated: Feb 4, 2026

Measurement of Factor V Activity in Human Plasma Using a Microplate Coagulation Assay
Published on: September 9, 2012
Basic coagulation tests as surrogates of dabigatran levels in a pre-operative setting: Analysis of five activated
Catherine Dubé1, James D Douketis2, Karen A Moffat3
1Département de médecine, Université de Montréal, Montreal, Canada.
Background:
In patients who are receiving dabigatran, a direct oral anticoagulant, measuring the anticoagulant effect before surgery may be needed in certain circumstances. Although the dilute thrombin time (dTT) can reliably measure dabigatran levels, it is not consistently available. More commonly used coagulation tests, including the activated partial thromboplastin time (aPTT) and thrombin time (TT) might have clinical utility but their accuracy is uncertain.
Methods:
103 patients stopped dabigatran 1-4 days before an elective surgery/procedure as part of a standardized dabigatran interruption protocol. With a blood sample taken just before surgery, we assessed the accuracy of five aPTT assays (Actin FS, Stago PTT, C.K. PREST, HemosIL aPTT-SP, SynthASil) and TT to measure the residual anticoagulant effect of dabigatran. We determined the sensitivity, specificity and other accuracy indices of these assays to predict a dabigatran level > 30 ng/mL as determined by a reference standard test, the dTT (Hemoclot).
Results:
Of five aPTT reagents, four assays had excellent (100%) and one assay had good (93%) sensitivity to detect a level of dabigatran > 30 ng/mL, but all had insufficient specificity (50-74%). A TT > 90 s had good sensitivity (93%) and excellent specificity (100%).
Conclusion:
Five aPTT assays had good sensitivity but poor specificity to detect low levels of dabigatran (≤30 ng/mL) after standardized dabigatran interruption before an elective surgery/procedure, thereby limiting the use of aPTT as an alternative to the dTT in preoperative settings.
Related Concept Videos
Setting Time of Cement
Basic Continuous Time Signals
The unit step function, denoted u(t), is zero for negative time values and one for positive time values, exhibiting a discontinuity at t=0. This function often represents abrupt changes, such as the step voltage introduced when turning a car's...
Basic Discrete Time Signals
The unit impulse or sample sequence is mathematically expressed as zero for all n values except at n=0, where it is one. The unit impulse sequence, denoted by δ(n), is the first difference of the unit step sequence, while the unit step sequence u(n) is the...
Basic Operations on Signals
Time Reversal mirrors a continuous-time signal about the vertical axis at t=0. This is achieved by substituting t with −t. For example, if a signal x(t) is considered, the time-reversed signal is x(−t). This operation can be graphically represented, showing the mirrored signal.
Noncompartmental Analysis: Mean Residence Time
After the administration of a drug through intravenous bolus injection, the drug molecules are distributed throughout the body and remain there for varying periods. The MRT represents the average time these drug molecules stay in the...
Noncompartmental Analysis: Mean Transit, Absorption and Dissolution Time
One of the key parameters is the mean transit time (MTT), which refers to the total duration required for drug molecules to transit through the body. MTT is determined by calculating the ratio of the area under the moment curve to the area...

