Related Experiment Video
Updated: Feb 4, 2026

Determining Binding Affinity KD of Radiolabeled Antibodies to Immobilized Antigens
Published on: June 23, 2022
Antibody immobilization strategy for the development of a capacitive immunosensor detecting zearalenone
Astrid Foubert1, Natalia V Beloglazova1, Martin Hedström2
1Ghent University, Faculty of Pharmaceutical Sciences, Laboratory of Food Analysis, Ottergemsesteenweg 460, Ghent, Belgium.
Abstract:
A highly sensitive flow-injection capacitive immunosensor was developed for detection of the mycotoxin zearalenone (ZEN). Different strategies for immobilization of an anti-ZEN antibody on the surface of a gold electrode, i.e. polytyramine or self-assembled monolayers (SAMs) of 3-mercaptopropionic acid (3-MPA) and lipoic acid (LA), were used and their performances were compared. The LA- and 3-MPA-based systems showed broad linear ranges for ZEN determination, i.e. from 0.010 nM to 10 nM and from 0.020 nM to 10 nM, respectively. Under optimal conditions, the LA-based immunosensor was capable of performing up till 13 regeneration-interaction cycles (with use of glycine HCl, pH 2.4) with a limit of detection (LOD) of 0.0060 nM, equivalent to 1.9 pg mL-1. It also demonstrated a good inter-assay precision (RSD < 10%). However, the tyramine-based capacitive immunosensor showed a bad repeatability (only 4 regeneration-interaction cycles were possible) and inter-assay precision (RSD > 15%) which did not allow sensitive and precise measurements. The LA-based method was compared with a direct ELISA. These results demonstrated that the label-free developed capacitive immunosensor had a better sensitivity and shorter analysis time in comparison with the direct microwell-plate format.
More Related Videos
Related Concept Videos
Equivalent Capacitance
Equivalent Capacitance
The following strategies are adopted to calculate...
Capacitors and Capacitance
When the conductors are two identical parallel plates, it is called a parallel plate capacitor. When battery terminals are...
Design Example: Capacitance Multiplier Circuit
The circuit illustrated in Figure 1 below incorporates two op-amps, with the first operating as a voltage follower and the second acting as an inverting amplifier.
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Antibody Structure
Antibodies, also known as immunoglobulins (Ig), are essential players of the adaptive immune system. These antigen-binding proteins are produced by B cells and make up 20 percent of the total blood plasma by weight. In mammals, antibodies fall into five different classes, which each elicits a different biological response upon antigen binding.
The Y-Shaped Structure of Antibodies Consists of Four Polypeptide Chains
Antibodies consist of four polypeptide chains: two identical heavy...

