Related Experiment Video
Updated: Feb 4, 2026

Synthesis and Functionalization of 3D Nano-graphene Materials: Graphene Aerogels and Graphene Macro Assemblies
Published on: November 5, 2015
Graphene reinforced multiple monolithic fiber solid-phase microextraction of phenoxyacetic acid herbicides in complex
Miao Pei1, XiaoLai Shi2, Jiangyi Wu1
1State Key Laboratory of Marine Environmental Science, Key Laboratory of the Ministry of Education for Coastal and Wetland Ecosystem, College of the Environment and Ecology, Xiamen University, P. O. Box 1009, Xiamen 361005, China.
Abstract:
To increase the specific surface area (SSA) of monolith-based adsorbent for the extraction of phenoxyacetic acid herbicides (PAAs) in complex samples, graphene was embedded in an adsorbent based on poly (4-vinylpyridine-co-ethylene glycol dimethacrylate) monolith (GEM). The new adsorbent was employed as extraction phase of multiple monolithic fiber solid-phase microextraction (MMF-SPME). The influences of preparation conditions and extraction parameters on the enrichment performance of GEM/MMF-SPME for PAAs were investigated in detail. Results well indicated that the embedded graphene could obviously enhance the SSA of the adsorbent and introduce π-π electrostatic stacking groups. The prepared GEM/MMF-SPME could extract PAAs effectively by means of π-π electrostatic stacking, hydrophobic, ion-exchange and hydrogen bonding interactions. Under the most favorable conditions, a convenient, sensitive, cost-effective and environmentally friendly method for the determination of trace PAAs in water and rice samples was developed by the combination of GEM/MMF-SPME and high performance liquid chromatography-diode array detection (HPLC-DAD). Results showed that for water sample, the limits of detection (LOD, S/N = 3) and limit of quantification (LOQ, S/N = 10) values were in the range of 0.093-0.12 μg/L and 0.31-0.41 μg/L, respectively. The corresponding values in rice sample were 0.36-0.66 μg/kg and 1.18-2.27 μg/kg, respectively. The proposed method was successfully applied to quantify trace PAAs in water and rice samples. Recoveries achieved for water and rice samples at different spiked concentrations were in the ranges of 70.0-118% and 70.0-117%, respectively. The RSDs varied from 0.3% to 10% for all analytes. The results well revealed the potential application of GEM/MMF-SPME as an effective sample preparation processes for the monitoring of PAAs in water, rice and other complex samples.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
09:20Microhoneycomb Monoliths Prepared by the Unidirectional Freeze-drying of Cellulose Nanofiber Based Sols: Method and Extensions
Published on: May 24, 2018
Related Concept Videos
Fiber Reinforced Concrete
Phase Diagrams
Reinforcement
Positive reinforcement occurs when a behavior is followed by the presentation of a rewarding stimulus, increasing the frequency of that behavior. For example:
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Protein Complex Assembly
Many viruses self-assemble into a fully functional unit using the infected host cell to...
Structures of Solids