RF Energy Harvesting and Information Transmission Based on NOMA for Wireless Powered IoT Relay Systems

Ashish Rauniyar1,2, Paal Engelstad3,4, Olav N Østerbø5

  • 1Autonomous System and Networks Research Group, Department of Computer Science, Oslo Metropolitan University, 0130 Oslo, Norway. ashish@oslomet.no.

Sensors (Basel, Switzerland)
|September 29, 2018
PubMed

Related Concept Videos

Power and Energy01:12

Power and Energy

The power and energy delivered to an element are subjects of great significance in the field of electrical engineering. It is a well-known fact that a 100-watt light bulb emits more light than a 60-watt one. Therefore, power and energy calculations play a crucial role in the analysis of electrical circuits.
Power, defined as the time rate of expending or absorbing energy, is quantified in units called watts (W). The relation between power and energy is mathematically given as
2.0K
Energy and Power Signals01:17

Energy and Power Signals

In an electrical system with a resistor, voltage and current signals facilitate the measurement of power and energy across the resistor. For a continuous-time signal, the total energy over a time interval is defined as the integral of the square of the signal's magnitude over that interval. Mathematically, this is expressed as:
1.2K
Energy and Power of a Wave00:58

Energy and Power of a Wave

The total energy associated with a wavelength is the sum of the potential energy and the kinetic energy. The average rate of energy transfer associated with a wave is called its power, which is total energy divided by the time it takes to transfer the energy. For a sinusoidal wave, energy and power are proportional to the square of both the amplitude and the angular frequency.
Waves can also be concentrated or spread out, as characterized by the intensity of the wave. Intensity is directly...
5.0K
Directional Relays01:25

Directional Relays

Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
618
Overcurrent Relays01:26

Overcurrent Relays

Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
545
Differential Relays01:20

Differential Relays

Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
776