Related Experiment Video
Updated: Feb 4, 2026

Assessment of Methane and Nitrous Oxide Fluxes from Paddy Field by Means of Static Closed Chambers Maintaining Plants Within Headspace
Published on: September 6, 2018
An analysis method for determining residual hexane in health functional food products using static headspace gas
Eun-Jeong Jeong1, Sang Hwa Lee2, Beom-Tea Kim3
11Department of Food Science and Technology, Chonbuk National University, Jeonju, Jeonbuk, 54896 Korea.
Abstract:
A method for analyzing the contents of residual hexane in health functional food products was developed. The dissolving solvents in the health functional food products and the internal standard selected were N,N-dimethylacetamide and heptane, respectively. The analysis conditions for headspace-gas chromatography/flame ionization detection (HS-GC/FID) and headspace-gas chromatography/mass spectrometry (HS-GC/MS) were determined as 18 mL of headspace volume, 100°C of headspace oven temperature, and 30 min of equilibration time; a Durabond (DB)-624 column was selected for this analysis. To validate this method, which applies N,N-dimethylacetamide as a dissolving solvent, the limit of detection and limit of quantification (LOQ) values based on the HS-GC/FID and HS-GC/MS analyses results were found to be 0.10, 0.29 and 0.16, 0.47 mg/L, respectively. The recoveries and coefficient of variation (CV) obtained by HS-GC/MS were 96.39-119.86% and 0.04-1.25%, respectively, better than those obtained by HS-GC/FID. By applying the HS-GC/MS method, it was possible to analyze the content of the residual hexane in 60 different types of health functional food products.
More Related Videos
10:11Microdialysis of Ethanol During Operant Ethanol Self-administration and Ethanol Determination by Gas Chromatography
Published on: September 5, 2012
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Chemical Stoichiometry and Gases: Using Ideal Gas Law to Determine Moles
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...