Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)01:15

Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)

1.1K
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT) is an advanced Nuclear Magnetic Resonance (NMR) technique specifically designed to detect and enhance the signals of low-abundance nuclei, such as carbon-13 and nitrogen-15, in small molecules. The fundamental principle behind INEPT is the transfer of polarization from a more abundant and highly polarizable nucleus, typically hydrogen-1, to the low-abundance nucleus of interest. This process effectively boosts the NMR signal of the...
1.1K
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

1.7K
When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.7K
Termination of Translation01:44

Termination of Translation

27.7K
The large ribosomal subunit has several important structures essential to translation. These include the peptidyl transferase center (PTC) - which is the site where the peptide bond is formed - and a large, internal, water-filled tube through which the nascent polypeptide moves. This latter structure is called the Peptide Exit Tunnel, and it begins at the PTC and spans the body of the large ribosomal subunit. During translation, as the nascent polypeptide chain is synthesized, it passes through...
27.7K
Protein-protein Interfaces02:04

Protein-protein Interfaces

14.7K
Many proteins form complexes to carry out their functions, making protein-protein interactions (PPIs) essential for an organism's survival. Most PPIs are stabilized by numerous weak noncovalent chemical forces. The physical shape of the interfaces determines the way two proteins interact. Many globular proteins have closely-matching shapes on their surfaces, which form a large number of weak bonds. Additionally, many PPIs occur between two helices or between a surface cleft and a...
14.7K
Group Polarization01:01

Group Polarization

39.2K
Group polarization is the strengthening of an original group attitude following the discussion of views within a group (Teger & Pruitt, 1967). That is, if a group initially favors a viewpoint, after discussion the group consensus is likely a stronger endorsement of the viewpoint. Conversely, if the group was initially opposed to a viewpoint, group discussion would likely lead to stronger opposition.
39.2K
Intermolecular Forces03:13

Intermolecular Forces

71.4K
Atoms and molecules interact through bonds (or forces): intramolecular and intermolecular. The forces are electrostatic as they arise from interactions (attractive or repulsive) between charged species (permanent, partial, or temporary charges) and exist with varying strengths between ions, polar, nonpolar, and neutral molecules. The different types of intermolecular forces are ion–dipole, dipole–dipole, hydrogen bonds, and dispersion; among these, dipole–dipole, hydrogen...
71.4K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Advancing non-faradaic impedance biosensors: sensitivity enhancement strategies using microfluidics, multiscale labeling, and CMOS technology.

Microsystems & nanoengineering·2026
Same author

Stabilization of adhesions controls F-actin architecture in mechanotransduction.

Communications materials·2025
Same author

Regulation of corneal stromal cell behavior by modulating curvature using a hydraulically-controlled organ chip array.

Nature communications·2025
Same author

Microfabricated Onsite Analyzer for Biomarkers (MOAB) for Automated Crew Health Monitoring.

ACS sensors·2025
Same author

Integrated process for lignin depolymerization and nanoparticle production using deep eutectic solvent.

Scientific reports·2025
Same author

Lignin-derived carbon flake sorbent for efficient oil-water separation.

International journal of biological macromolecules·2025

Related Experiment Video

Updated: Feb 4, 2026

Digital Microfluidics for Automated Proteomic Processing
10:55

Digital Microfluidics for Automated Proteomic Processing

Published on: November 6, 2009

13.0K

Digital microfluidics using a differentially polarized interface (DPI) to enhance translational force.

Md Enayet Razu1, Jungkyu Kim

  • 1Department of Mechanical Engineering, Texas Tech University, Lubbock, Texas 79409, USA. jungkyu.kim@ttu.edu.

Lab on a Chip
|September 29, 2018
PubMed
Summary

Direct current-digital microfluidics (DC-DMF) can now operate at lower voltages without oil fillers. A new differentially polarized interface (DPI) method reduces voltage requirements for droplet manipulation, enhancing DC-DMF applications.

More Related Videos

An In vitro Model to Study Heterogeneity of Human Macrophage Differentiation and Polarization
07:42

An In vitro Model to Study Heterogeneity of Human Macrophage Differentiation and Polarization

Published on: June 12, 2013

19.5K
A Versatile Kit Based on Digital Microfluidics Droplet Actuation for Science Education
05:46

A Versatile Kit Based on Digital Microfluidics Droplet Actuation for Science Education

Published on: April 26, 2021

5.3K

Related Experiment Videos

Last Updated: Feb 4, 2026

Digital Microfluidics for Automated Proteomic Processing
10:55

Digital Microfluidics for Automated Proteomic Processing

Published on: November 6, 2009

13.0K
An In vitro Model to Study Heterogeneity of Human Macrophage Differentiation and Polarization
07:42

An In vitro Model to Study Heterogeneity of Human Macrophage Differentiation and Polarization

Published on: June 12, 2013

19.5K
A Versatile Kit Based on Digital Microfluidics Droplet Actuation for Science Education
05:46

A Versatile Kit Based on Digital Microfluidics Droplet Actuation for Science Education

Published on: April 26, 2021

5.3K

Area of Science:

  • Microfluidics
  • Electromechanical Systems
  • Surface Science

Background:

  • Direct current-digital microfluidics (DC-DMF) is crucial for diagnostics and assays but requires high voltages, risking dielectric breakdown and electrolysis.
  • Current solutions involve oil-fillers to reduce voltage, but this adds complexity and limits versatility.

Purpose of the Study:

  • To develop a low-voltage, filler-less DC-DMF method.
  • To reduce the operational voltage for droplet manipulation.
  • To differentiate electrowetting and electromechanical forces in droplet movement.

Main Methods:

  • Adaptation of a differentially polarized interface (DPI) to generate electromechanical force.
  • Analysis of contact angle temporal profiles during droplet motion.
  • Comparison of droplet manipulation with and without oil-fillers.

Main Results:

  • Reduced droplet manipulation voltage from 600 V to 85 V without oil-fillers.
  • Electrowetting dominates initial droplet movement (52.8% advancing, 20% receding contact angle reduction).
  • Electromechanical forces become predominant after contact angle temporal changes saturate.

Conclusions:

  • DPI-based DC-DMF significantly lowers voltage requirements and complexity.
  • This method enables filler-less, low-voltage manipulation of diverse liquid samples.
  • The findings pave the way for more cost-effective and versatile microfluidic devices.