Related Experiment Video For Au NPs/NH(2)-GS
Updated: Feb 4, 2026

Fabrication of Amperometric Electrodes
Published on: May 4, 2009
A sandwich-type amperometric immunosensor fabricated by Au@Pd NDs/Fe2+-CS/PPy NTs and Au NPs/NH2-GS to detect CEA
Fubin Pei1, Ping Wang1, Enhui Ma1
1School of Chemistry and Chemical Engineering, Shandong University of Technology, 255049 Zibo, PR China.
Abstract:
The quantitative detection of carcinoembryonic antigen (CEA) is significant to assess tumor status and therapeutic efficiency. In this study, a sandwich-type amperometric immunosensor for CEA detection sensitively was fabricated by novel signal amplification system. The signal amplification system was formed by gold nanoparticles loaded on amino functionalized graphene sheet (Au NPs/NH2-GS) and gold@palladium nanodendrites loaded on ferrous-chitosan functionalized polypyrrole nanotubes (Au@Pd NDs/Fe2+-CS/PPy NTs). Au NPs/NH2-GS as platform enhanced the electron transfer proven by apparent electron transfer rate constant. Au@Pd NDs/Fe2+-CS/PPy NTs nanocomposite as label appeared high catalytic activity to hydrogen peroxide reduction. Thus, the immunosensor showed wide linear concentration range (50 fg/mL to 50 ng/mL) and low detection limit of 17 fg/mL via amperometric i-t curve (i-t). Significantly, the nanocomposite can act as electroactive substance, which provided a good method to detect CEA without additional electroactive substance via square wave voltammetry (SWV). An overlapping linear concentration range (500 fg/mL to 5.0 ng/mL) was obtained compared i-t with SWV. The good reliability was verified mutually by i-t and SWV in actual sample analysis under overlapping linear concentration range. The detection method of without additional electroactive substance has vast potential for future development, due to simple testing condition.
Related Concept Videos
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...