Rapid in situ determination of heavy metal concentrations in polluted water via portable XRF: Using Cu and Pb as example
Related Experiment Video
Updated: Feb 4, 2026

Quantification of Heavy Metals and Other Inorganic Contaminants on the Productivity of Microalgae
Published on: July 10, 2015
Shubin Zhou1, Zhaoxian Yuan2, Qiuming Cheng1
1State Key Lab of Geological Processes and Mineral Resources, China University of Geosciences, Beijing, 100083, China.
Abstract:
In this research, the effectiveness of using portable X-ray fluorescence (pXRF), with the help of waterproof film, to determine the concentration of the heavy metals Cu and Pb in polluted water was assessed through indoor and field studies. The effects of the thickness of the film and the distance between the instrument and sample were also evaluated. The penetration depth of X-rays in water was found to be between 2 mm and 4 mm, and a water sample of at least 4 mm in depth was thus suggested. The minimum detectable concentration for Cu was ca. 21 ppm and ca. 28 ppm for Pb. Based on the indoor study, the pXRF results were found to be comparable with the certified concentrations of prepared solutions (R2 > 0.99 for both Cu and Pb). The field pXRF readings also showed a good linear correlation with the corresponding laboratory results (R2 > 0.95 for Cu). The calibration formula derived from indoor analysis was used to correct the field pXRF results and effectively improved the accuracy. Consequently, pXRF has the potential to be applied to the analysis of polluted waters with relatively high concentrations (e.g., >20-30 ppm Cu), which would benefit the in situ monitoring of water pollution caused by heavy metals.
More Related Videos
08:55Methods of Ex Situ and In Situ Investigations of Structural Transformations: The Case of Crystallization of Metallic Glasses
Published on: June 7, 2018
05:52Resource Recycling of Red Soil to Synthesize Fe2O3/FAU-type Zeolite Composite Material for Heavy Metal Removal
Published on: June 2, 2022
Related Concept Videos
Bonding in Metals
Alkali Metals
Table 1: Properties of the alkali metals
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Concentration Cells
Consider the following voltaic cell:
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Expressing Solution Concentration
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.