Evaluation of beam matching accuracy among six linacs from the same vendor
Chockkalingam Krishnappan1,2, Chandrasekaran Anu Radha3, Karunakaran Balaji3,4,5
1Department of Medical Physics, Apollo CBCC Hospitals, Gandhinagar, Gujarat, 382428, India. c.krishnappan@gmail.com.
Abstract:
The purpose of this study was to evaluate the dosimetric variation among six non-beam-matched Varian linacs using different techniques for the same plans. Six non-beam-matched Varian machines, comprising two Clinac iX, two 600 C/D (Unique), and two True Beam Tx photon 6 MV X-ray devices were acquired. Sixty patients with of head and neck (H&N; 30) and pelvic (30) treatment sites were chosen. For all 60 patients, three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and volumetric-modulated radiotherapy (VMAT) plans were generated for the Clinac iX-1 device; all plans were migrated to the remaining machines, using the eclipse treatment planning system without any modification. The dosimetric variation among the six machines for each target volume and organ at risk was recorded and analyzed. In H&N cases, the maximum variation among the six machines with 3DCRT, IMRT, and VMAT was 2.57%, 2.6%, and 2.6%, respectively. In pelvic cases, the maximum variation among the six machines with 3DCRT, IMRT, and VMAT was 2.2%, 1.95%, and 2.05%, respectively. Our overall results show that dosimetric variation, while interchanging the plans among the six machines at phantom and patient levels, remains within the limits of clinical acceptability. The noted variation was not correlated with any of these treatment techniques: 3DCRT, IMRT, or VMAT.
More Related Videos
08:08Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
07:28A Method for Evaluating Timeliness and Accuracy of Volitional Motor Responses to Vibrotactile Stimuli
Published on: August 2, 2016
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Sign Test for Matched Pairs
To conduct the sign test, we first calculate the differences in...
Uncertainty in Measurement: Accuracy and Precision
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Accuracy and Precision