The validation of smartphone applications for heart rate measurement
Weenita Pipitprapat1, Sarawin Harnchoowong1, Poonkiat Suchonwanit1
1a Department of Medicine , Faculty of Medicine Ramathibodi Hospital, Mahidol University , Bangkok , Thailand.
Background:
The smartphone apps provide a user-friendly option for measurement of heart rate (HR) by detecting pulsatile photoplethysmographic signals with built-in cameras from the fingertips, however, the validation study is limited.
Methods:
We compared HR detected by the smartphone apps (App1 = Instant HR, App2 = Cardiio: HR Monitor and App3 = Runtastic HR Monitor) with simultaneous standard ECG monitoring in the adult patients at the critical care unit.
Results:
HR measurements were obtained from 140 patients with mean age 67.6 ± 15.3 years. Mean baseline HR was 89.1 ± 19.1 bpm (range, 32-136 bpm). Sinus rhythm was presented in 111 patients (79.3%), atrial fibrillation in 25 patients (17.9%), pacemaker rhythm in 3 patients (2.1%), and high-grade AV block in 1 patient (0.7%). The ECG-derived HR correlated well with App1 (r = 0.98), App2 (r = 0.97), and App3 (r = 0.92). In patients with regular rhythm, mean absolute deviation was 0.8 ± 1, 0.7 ± 0.9, 1.0 ± 1.3 bpm on App1, App2 and App3, respectively. In the patients with irregular rhythm, median absolute deviation (IQR) was 3 (2-5.5), 4 (1.5-11.5), and 6 (2-13) bpm. Skin colour did not affect with the HR measurement.
Conclusions:
HR measurements from all applications were correlated well with ECG monitoring. However, it was less accurate in case of irregular rhythm such as atrial fibrillation. Key messages Several reports on inaccuracy of mobile health apps have been published. We conducted the validation study in the real patients by using popular mobile apps. Heart rate measurements from mobile apps were correlated well with standard ECG. The accuracy of HR from apps was worse at irregular rate and tachycardia.
Related Concept Videos
Measuring Reaction Rates
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Application of Rates of Change
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Reliability and Validity
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...