Quantitative Analysis of Vacuum Induction Melting by Laser-induced Breakdown Spectroscopy
Published on: June 10, 2019
Quantitative Analysis of Cadmium in Tobacco Roots Using Laser-Induced Breakdown Spectroscopy With Variable Index and
Fei Liu1,2, Tingting Shen1, Wenwen Kong1,3
1College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, China.
Abstract:
The study investigated some new developed variable indices and chemometrics for the fast detection of cadmium (Cd) in tobacco root samples by laser-induced breakdown spectroscopy. The variables selection methods of interval partial least squares (iPLS), backward interval partial least squares (BiPLS), and successive projections algorithm (SPA) were used to locate the optimal Cd emission line for univariate analysis and to select the maximal relevant variables for multivariate analysis. iPLS and BiPLS located 10 Cd emission lines to establish univariate analysis models. Univariate analysis model based on Cd I (508.58 nm) performed best with the coefficient of determination of prediction (R 2) of 0.9426 and root mean square error of prediction (RMSEP) of 1.060 mg g-1. We developed two new variable indices to remove negative effects for Cd content prediction, including Index1 = (I 508.58 + I 361.05)/2 × I 466.23 and Index2 = I 508.58/I 466.23 based on Cd emission lines at 508.58, 361.05, and 466.23 nm. Univariate model based on Index2 obtained better result (R 2 of 0.9502 and RMSEP of 0.988 mg g-1) than univariate analysis based on the best Cd emission line at 508.58 nm. PLS and support vector machines (SVM) were adopted and compared for multivariate analysis. The results of multivariate analysis outperformed univariate analysis and the best quantitative model was achieved by the iPLS-SVM model (R 2 of 0.9820, RMSECV of 0.214 mg g-1, R 2 of 0.9759, and RMSEP of 0.712 mg g-1) using the maximal relevant variables in the range of 474-526 nm. The results indicated that LIBS coupled with new developed variable index and chemometrics could provide a feasible, effective, and economical approach for fast detecting Cd in tobacco roots.
More Related Videos
10:17Laser-induced Breakdown Spectroscopy: A New Approach for Nanoparticle's Mapping and Quantification in Organ Tissue
Published on: June 18, 2014
08:53Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
Related Concept Videos
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Graphs of Equations in Two Variables
Variables Affecting Phosphorescence and Fluorescence
Primary and Secondary Growth in Roots and Shoots