Standardized Measurement of Nasal Membrane Transepithelial Potential Difference NPD
Published on: September 13, 2018
Standardized Measurement of Nasal Membrane Transepithelial Potential Difference (NPD)
George M Solomon1, Inez Bronsveld2, Kathryn Hayes3
1Department of Medicine and the Gregory Fleming James Cystic Fibrosis Center, University of Alabama at Birmingham.
Abstract:
We describe a standardized measurement of nasal potential difference (NPD). In this technique, cystic fibrosis transmembrane conductance regulator (CFTR) and the epithelial sodium channel (ENaC) function are monitored by the change in voltage across the nasal epithelium after the superfusion of solutions that modify ion channel activity. This is enabled by the measurement of the potential difference between the subcutaneous compartment and the airway epithelium in the nostril, utilizing a catheter in contact with the inferior nasal turbinate. The test allows the measurement of the stable baseline voltage and the successive net voltage changes after perfusion of 100 µM amiloride, an inhibitor of Na+ reabsorption in Ringer's solution; a chloride-free solution containing amiloride to drive chloride secretion and 10 µM isoproterenol in a chloride-free solution with amiloride to stimulate the cyclic adenosine monophosphate (cAMP)-dependent chloride conductance related to CFTR. This technique has the advantage of demonstrating the electrophysiological properties of two key components establishing the hydration of the airway surface liquid of the respiratory epithelium, ENaC, and CFTR. Therefore, it is a useful research tool for phase 2 and proof of concept trials of agents that target CFTR and ENaC activity for the treatment of cystic fibrosis (CF) lung disease. It is also a key follow-up procedure to establish CFTR dysfunction when genetic testing and sweat testing are equivocal. Unlike sweat chloride, the test is relatively more time consuming and costly. It also requires operator training and expertise to conduct the test effectively. Inter- and intra-subject variability has been reported in this technique especially in young or uncooperative subjects. To assist with this concern, interpretation has been improved through a recently validated algorithm.
More Related Videos
Related Concept Videos
Standard Electrode Potentials
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
The Resting Membrane Potential
Measurement: Standard Units
Resting Membrane Potential
The Inside of a Neuron is More Negative
The membrane potential of a cell can be measured by inserting a microelectrode into a cell and comparing the charge to a reference electrode in the extracellular fluid. The...
Units and Standards of Measurement
Measurements of physical quantities are...