Detection of Methylated SEPT9 in Korean Colorectal Cancer Patients: Comparison with Previous Studies
Related Experiment Video
Updated: Feb 4, 2026

Detection of a Circulating MicroRNA Custom Panel in Patients with Metastatic Colorectal Cancer
Published on: March 14, 2019
Background:
This study aimed to investigate the detection of methylated Septin 9 (mSEPT9) in Korean patients with colorectal cancer (CRC) and compare the results with those of previous studies.
Methods:
A total of 127 plasma samples (111 patients with untreated CRC, 5 patients with adenomas, and 11 CRC patients treated with concurrent chemoradiotherapy before surgery) were collected. mSEPT9 was measured qualitatively with the Abbott RealTime ms9 Colorectal Cancer Assay.
Results:
mSEPT9 was detected in 44 of 111 (39.6%) cases of untreated CRC but was not detected in the adenoma cases. The difference in the sensitivity of mSEPT9 among patients with adenomas and those with each stage of untreated CRC was statistically significant (Dukes' staging, p = 0.002 and TNM staging, p = 0.008). The sensitivity of mSEPT9 for each of the stages (I - IV) of untreated CRC patients were 20.7%, 54.1%, 36.6%, and 75.0%, respectively. The positive mSEPT9 results in untreated CRC patients reverted to negative in 19 of 21 patients (90.5%) after treatment.
Conclusions:
Compared to previous studies, the overall sensitivity of mSEPT9 was lower, but similar patterns were found in the sensitivities for each stage. Additionally, mSEPT9 appeared to have potential as a monitoring tool for CRC.
More Related Videos
06:49Orthotopic Implantation of Patient-Derived Cancer Cells in Mice Recapitulates Advanced Colorectal Cancer
Published on: February 10, 2023
06:46Competing-Risk Nomogram for Predicting Cancer-Specific Survival in Multiple Primary Colorectal Cancer Patients after Surgery
Published on: September 27, 2024
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Mouse Models of Cancer Study
The development of transgenic, knockout, and knock-in mice has led to an exponential increase in their use as model organisms in research,...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Bioavailability Study Design: Healthy Subjects Versus Patients
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...