Related Experiment Video
Updated: Feb 4, 2026

Imaging Features of Systemic Sclerosis-Associated Interstitial Lung Disease
Published on: June 16, 2020
Performance of Forced Vital Capacity and Lung Diffusion Cutpoints for Associated Radiographic Interstitial Lung
Kimberly Showalter1,2, Aileen Hoffmann1,2, Gerald Rouleau1,2
1From the Department of Medicine, Division of Rheumatology, Division of Pulmonary and Critical Care Medicine, Department of Preventive Medicine, Institute for Public Health and Medicine, Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.
Objective:
Forced vital capacity (FVC) and DLCO are used for screening of systemic sclerosis-associated interstitial lung disease (SSc-ILD). The study purpose was to determine the sensitivity, specificity, and negative predictive value (NPV) (proportion of true negative screening tests) of FVC and DLCO thresholds for SSc-ILD on chest high-resolution computed tomography (HRCT) scans.
Methods:
Patients fulfilling American College of Rheumatology 2013 SSc criteria with a chest HRCT scan and pulmonary function tests (PFT) were studied. A thoracic radiologist quantified radiographic ILD. Optimal FVC and DLCO % predicted thresholds for ILD were identified using receiver-operating characteristic curves. The FVC and DLCO combinations with greatest sensitivity and specificity were also determined. Subanalysis was performed in patients with positive Scl-70 autoantibodies.
Results:
The study included 265 patients. Of 188 (71%) with radiographic ILD, 59 (31%) had "normal" FVC (≥ 80% predicted), and 65 out of 151 (43%) had "normal" DLCO (≥ 60% predicted). FVC < 80% (sensitivity 0.69, specificity 0.73), and DLCO < 62% (sensitivity 0.60, specificity 0.70) were optimal thresholds for radiographic SSc-ILD. All FVC and DLCO threshold combinations evaluated had NPV < 0.70. The NPV for radiographic ILD for FVC < 80% was lower in patients with positive Scl-70 autoantibody (NPV = 0.05) compared to negative Scl-70 autoantibody (NPV = 0.57).
Conclusion:
Radiographic ILD is prevalent in SSc despite "normal" PFT. No % predicted FVC or DLCO threshold combinations yielded high NPV for SSc-ILD screening. "Normal" FVC and DLCO in patients with SSc, especially those with positive Scl-70 autoantibodies, should not obviate consideration of HRCT for ILD evaluation.
Related Concept Videos
Lung Capacity
Pleura of the Lungs
Gross Anatomy of the Lungs
Diffusion
Diffusion
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...