Two-dimensional noise reconstruction in proton computed tomography using distance-driven filtered back-projection of
Martin Rädler1,2, Guillaume Landry1,2, Simon Rit3
1Department of Medical Physics, Ludwig-Maximilians-Universität München, 85748 Garching b. München, Germany.
Abstract:
We present a formalism for two-dimensional (2D) noise reconstruction in proton computed tomography (pCT). This is necessary for the application of fluence modulated pCT (FMpCT) since it permits image noise prescription and the corresponding proton fuence optimization. We aimed at extending previously published formalisms to account for the impact of multiple Coulomb scattering (MCS) on projection noise, and the use of filtered back projection (FBP) reconstruction along curved paths with distance driven binning (DDB). 2D noise reconstruction for a beam of protons with parallel initial momentum vectors, and for projections binned both at the rear tracker and with DDB, was established. Monte Carlo (MC) simulations of pCT scans of a water cylinder were employed to generate pCT projections and to calculate their noise for use in 2D noise reconstruction. These were compared to results from an analytical model accounting for MCS for rear tracker binning as well as against the previously published central pixel model which ignores MCS. Image noise reconstructed with the formalism for rear tracker binning and DDB were compared to MC results using annular regions of interest (ROIs). Agreement better than 8% was obtained between the noise of projections calculated with MC simulation and our model. Noise from annular ROIs agreed with our noise reconstructions for rear tracker binning and DDB. The central pixel model ignoring MCS underestimated projection and thus image noise by up to 40% towards the object's edge. The use of DDB decreased the image noise towards the object's edge when compared to rear tracker binning and yielded more uniform noise throughout the image. MCS should not be neglected when predicting image noise for pixels away from the center of an object in a pCT scan due to the increasing influence of the gradient of the object's hull closer to the edges.
More Related Videos
Related Concept Videos
Fischer Projections
Newman Projections
The organic molecules rotate across the single bonds leading to numerous temporary three-dimensional structures of varying energy known as...
Coordinates and Map Projections
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...