Related Experiment Video
Updated: Feb 4, 2026

Accessing the Subdural Space of the Rodent Spinal Cord for Treatment Delivery
Published on: August 8, 2025
Methanol Detected in a Subdural Hematoma as an Embalming Artifact
Robert H Powers1, Benjamin E Criss2, Robert G Topmiller3
1Department of Forensic Sciences, University of New Haven, 300 Boston Post Road, West Haven, CT, 06516.
Abstract:
Analysis of subdural hematomata has been used to suggest antemortem drug concentrations, with the assumption that materials within the hematoma are less subject to metabolism or degradation during any survival period and postmortem interval. We report the case of an 87-year-old woman whose death had not been reported to the coroner's office until postembalming. Autopsy revealed a traumatic brain injury with subdural hematoma causing a mass effect. Testing of the clot indicated a methanol concentration of 51.8 mg%. No additional analyses were detected. These findings suggest that methanol can be present in a postmortem hematoma sample, yet not represent a poisoning. Our findings also suggest that while the interior of hematomata do not necessarily represent completely "protected space" from postmortem diffusion of some blood constituents, such diffusion is not facile, and analysis may still provide useful indications of antemortem drugs present, if not actual concentrations.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...

