Tunnel diode resonator for precision magnetic susceptibility measurements in a mK temperature range and large DC
Hyunsoo Kim1, M A Tanatar1, R Prozorov1
1Ames Laboratory, Ames, Iowa 50011, USA.
Abstract:
Precision radio-frequency measurements of the magnetic susceptibility using the tunnel diode resonator (TDR) technique are used to study the delicate effects in magnetic and superconducting materials. High resolution (in ppb range) measurements are particularly important for studies of the London and Campbell penetration depths in a superconductor and for the investigation of magnetic transitions in (anti)ferromagnets. Due to the small rf magnetic-excitation in a mOe range, the TDR is especially useful at low-temperatures in a mK range, if Joule heating generated in the TDR circuitry is efficiently removed and the circuit is stabilized with sub-mK precision. Unfortunately, the circuit has significant magnetic field dependence, and therefore, most of the precision TDR measurements at low-temperatures were conducted in zero magnetic field. In this work, we describe the design of a setup for precision TDR measurements in a dilution refrigerator down to ∼40 mK with a 14 T superconducting magnet. The key features of our design are the separated electronics components and the placement of the most field sensitive parts in the field-compensated zone far from the center of solenoid as well as the heat-sinking at a higher temperature stage. The performance of the working setup is demonstrated using several superconductors.
More Related Videos
13:56The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
Published on: November 19, 2014
10:21Metabolic Support of Excised, Living Brain Tissues During Magnetic Resonance Microscopy Acquisition
Published on: October 18, 2017
Related Concept Videos
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Magnetic Resonance Imaging
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Magnetic Field Lines
Magnetic field lines follow several hard-and-fast rules:
Energy In A Magnetic Field
Take an ideal inductor with zero resistance. Although it's practically impossible, assume that the coil's resistance is so small that it is practically negligible. The loss of the field's energy to dissipate thermal energy (or heat) is thus...