Related Experiment Video
Updated: Feb 4, 2026

Stenosis of the Inferior Vena Cava: A Murine Model of Deep Vein Thrombosis
Published on: December 22, 2017
Penetration of inferior vena cava filter strut through an introducer sheath inserted from the left internal jugular
Satoshi Yoshimura1, Seiji Koga1, Tomoo Nakata1
1Department of Cardiovascular Medicine, Nagasaki University Hospital, Nagasaki, Japan.
The report describes a case of penetration of an inferior vena cava filter (IVCF) strut through an introducer sheath inserted from the left internal jugular vein. A 64-year-old woman was admitted to our hospital with pulmonary embolism and lower extremity deep vein thrombosis. We attempted to implant a retrievable type IVCF via the left internal jugular vein. However, an unexpected resistance occurred during the advancement of the filter after passing the first few inches within the 8-Fr introducer sheath. Immediately, we checked the insertion site using fluoroscopy, which demonstrated penetration of the filter struts to the outside of the sheath. We speculate that a strong angulation in the vessel from the left internal jugular to superior vena cava might have contributed to this rare complication. <Learning objective: Penetration of an inferior vena cava filter (IVCF) strut through an introducer sheath is a rare complication. However, physicians should recognize that this complication could occur in cases of IVCF placement, especially when insertion is done via the left internal jugular vein.>.
The report describes a case of penetration of an inferior vena cava filter (IVCF) strut through an introducer sheath inserted from the left internal jugular vein. A 64-year-old woman was admitted to our hospital with pulmonary embolism and lower extremity deep vein thrombosis. We attempted to implant a retrievable type IVCF via the left internal jugular vein. However, an unexpected resistance occurred during the advancement of the filter after passing the first few inches within the 8-Fr introducer sheath. Immediately, we checked the insertion site using fluoroscopy, which demonstrated penetration of the filter struts to the outside of the sheath. We speculate that a strong angulation in the vessel from the left internal jugular to superior vena cava might have contributed to this rare complication. <Learning objective: Penetration of an inferior vena cava filter (IVCF) strut through an introducer sheath is a rare complication. However, physicians should recognize that this complication could occur in cases of IVCF placement, especially when insertion is done via the left internal jugular vein.>.
Related Concept Videos
Anatomy of the Circulatory System
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Active Filters
Internal Energy
Internal Receptors
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...