Related Experiment Video
Updated: Feb 4, 2026

Retinal Pigment Epithelium Transplantation in a Non-human Primate Model for Degenerative Retinal Diseases
Published on: June 14, 2021
Differences in Static and Kinetic Perimetry Results are Eliminated in Retinal Disease when Psychophysical Procedures
Jack Phu1,2, Michael Kalloniatis1,2, Henrietta Wang1,2
1Centre for Eye Health, University of New South Wales, Kensington, NSW, Australia.
Purpose:
We tested the hypothesis that clinical statokinetic dissociation (SKD, defined as the difference in sensitivity to static and kinetic stimuli) at the scotoma border in retinal disease is due to individual criterion bias and that SKD can be eliminated by equating the psychophysical procedures for testing static and kinetic stimulus detection.
Methods:
Six subjects with glaucoma and six with retinitis pigmentosa (RP) were tested. Clinical procedures (standard automated perimetry [SAP] and manual kinetic perimetry [MKP]) were used to determine clinical SKD and the region of interest for laboratory-based testing. Two-way Method of Limits (MoL) was used to establish the isocontrast region at the scotoma border in glaucoma and RP subjects. Method of Constant Stimuli (MoCS) and a two-interval forced choice (2IFC) procedure then were used to present static or kinetic (inward or outward) stimuli at different eccentricities within the isocontrast region. The results were fitted with psychometric functions to determine threshold eccentricities.
Results:
Clinical SKD was found in glaucoma and RP subjects, with variable magnitude among subjects, but significantly exceeding expected typical measurement variability. The resultant psychometric functions when using MoCS and 2IFC showed equal sensitivity to static and kinetic targets, thus eliminating SKD.
Conclusions:
Clinical SKD found using clinical techniques is due to methodologic differences and criterion bias, and is eliminated by using an equated and more objective psychophysical task, similar to normal subjects.
Translational Relevance:
Eliminating SKD using a psychophysical approach minimizing criterion bias suggests that it is not useful to distinguish between normal and diseased fields.
Related Concept Videos
Elimination Kinetics: First-Order and Zero-Order
Drug clearance depends on the rate of drug elimination and its plasma concentration. Another important parameter is a drug's half-life, which is the time required for its concentration to decrease by half. In most cases, drug clearance follows first-order...
Kinetics of Drug Elimination
Drug clearance depends on the rate of drug elimination and its plasma concentration. Another important parameter is the half-life of a drug, which is the time required for its concentration to decrease by half. In most cases, drug clearance follows first-order...
Static and Kinetic Frictional Force
However, if two systems are in contact and are stationary relative to one...
Difference Equation Solution using z-Transform
The z-transform facilitates handling delayed signals by shifting the signal in the z-domain, which corresponds to delaying the signal in the time domain, and advancing signals by similarly shifting in the...
Kinetic Molecular Theory: Molecular Velocities, Temperature, and Kinetic Energy
The Nernst Equation
The interconnection between standard cell potentials and various thermodynamic parameters such as the standard free energy change ΔG° and equilibrium constant K has been previously explored. For example, a redox reaction involving zinc(II) and tin(II) ions at 1 M concentration with Eºcell = +0.291 V and ΔG° = −56.2 kJ is spontaneous.

