Related Experiment Video
Updated: Feb 4, 2026

In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
Survival and Functional Status After Bridge-to-Transplant with a Left Ventricular Assist Device
Alejandro Suarez-Pierre1, Xun Zhou, Charles D Fraser
1From the Division of Cardiac Surgery, Department of Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland.
Abstract:
The use left ventricular assist devices (LVAD) as a bridge-to-transplant (BTT) has become a common modality to treat end-stage heart failure. We sought to examine the impact of BTT on long-term survival and quality of life after heart transplant. The population was all adult patients undergoing isolated heart transplantation in the United States between 2007 and 2017. Inclusion criteria covered BTT patients with a LVAD (only Heartmate II [HMII] or HeartWare Ventricular Assist System [HVAD]) and compared these with patients undergoing de novo heart transplantation. Our primary end-point was survival at 1, 2, and 5 years. Secondary end-points were functional status, return to work, and rates of hospital readmission and graft rejection. Unconditional and conditional survival was estimated with the Kaplan-Meier method. The independent influence of BTT on risk-adjusted mortality was determined using Cox proportional hazards models. In this period, 5,584 patients were bridged with an LVAD and 12,295 underwent de novo transplantation. Unconditional survival was 2% higher in de novo patients at 1, 2, and 5 years. After risk adjustment, BTT was associated with increased mortality at each time point. Unadjusted 5 year survival, conditional on 90 day survival, was similar between groups (82.6% vs. 83.4%; p = 0.15). Functional status, return to work, and unadjusted rates of hospital readmission and graft rejection were similar at 1, 2, 5 years. Bridge-to-transplant with LVADs provides excellent survival and similar quality of life to that of patients undergoing de novo heart transplantation. Bridge-to-transplant patients experience a slightly higher mortality rate within 90 days of transplantation.
Related Concept Videos
Design Example: Strain Gauge Bridge or Wheatstone Bridge
Wheatstone Bridge
Thus, for accurate resistance measurements, a...
Bridge rectifier
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Cross-bridge Cycle
Survival Curves
The Kaplan-Meier estimator is the most common method for constructing survival curves. This...
Survival Tree
Building a Survival Tree
Constructing a...

