Evaluation of lung toxicity risk with computed tomography ventilation image for thoracic cancer patients
Masakazu Otsuka1, Hajime Monzen1,2, Kenji Matsumoto1
1Department of Medical Physics, Graduate School of Medical Science, Kindai University, Osakasayama, Japan.
Background:
Four-dimensional computed tomography (4D-CT) ventilation is an emerging imaging modality. Functional avoidance of regions according to 4D-CT ventilation may reduce lung toxicity after radiation therapy. This study evaluated associations between 4D-CT ventilation-based dosimetric parameters and clinical outcomes.
Methods:
Pre-treatment 4D-CT data were used to retrospectively construct ventilation images for 40 thoracic cancer patients retrospectively. Fifteen patients were treated with conventional radiation therapy, 6 patients with hyperfractionated radiation therapy and 19 patients with stereotactic body radiation therapy (SBRT). Ventilation images were calculated from 4D-CT data using a deformable image registration and Jacobian-based algorithm. Each ventilation map was normalized by converting it to percentile images. Ventilation-based dosimetric parameters (Mean Dose, V5 [percent lung volume receiving ≥5 Gy], and V20 [percent lung volume receiving ≥20 Gy]) were calculated for highly and poorly ventilated regions. To test whether the ventilation-based dosimetric parameters could be used predict radiation pneumonitis of ≥Grade 2, the area under the curve (AUC) was determined from the receiver operating characteristic analysis.
Results:
For Mean Dose, poorly ventilated lung regions in the 0-30% range showed the highest AUC value (0.809; 95% confidence interval [CI], 0.663-0.955). For V20, poorly ventilated lung regions in the 0-20% range had the highest AUC value (0.774; 95% [CI], 0.598-0.915), and for V5, poorly ventilated lung regions in the 0-30% range had the highest AUC value (0.843; 95% [CI], 0.732-0.954). The highest AUC values for Mean Dose, V20, and V5 were obtained in poorly ventilated regions. There were significant differences in all dosimetric parameters between radiation pneumonitis of Grade 1 and Grade ≥2.
Conclusions:
Poorly ventilated lung regions identified on 4D-CT had higher AUC values than highly ventilated regions, suggesting that functional planning based on poorly ventilated regions may reduce the risk of lung toxicity in radiation therapy.
More Related Videos
05:56Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Thoracic Aorta
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
The Thoracic Cage: Sternum
The sternum is the elongated bony structure on the anterior side of the thoracic cage. It consists of three parts: the manubrium, the body, and the xiphoid...