Related Experiment Video
Updated: Feb 4, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
TIMP3 and TIMP1 are risk genes for bicuspid aortic valve and aortopathy in Turner syndrome
Holly Corbitt1,2, Shaine A Morris3, Claus H Gravholt4,5
1Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, United States of America.
Abstract:
Turner syndrome is caused by complete or partial loss of the second sex chromosome, occurring in ~1 in 2,000 female births. There is a greatly increased incidence of aortopathy of unknown etiology, including bicuspid aortic valve (BAV), thoracic aortic aneurysms, aortic dissection and rupture. We performed whole exome sequencing on 188 Turner syndrome participants from the National Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Related Conditions (GenTAC). A gene-based burden test, the optimal sequence kernel association test (SKAT-O), was used to evaluate the data with BAV and aortic dimension z-scores as covariates. Genes on chromosome Xp were analyzed for the potential to contribute to aortopathy when hemizygous. Exome analysis revealed that TIMP3 was associated with indices of aortopathy at exome-wide significance (p = 2.27 x 10(-7)), which was replicated in a separate cohort. The analysis of Xp genes revealed that TIMP1, which is a functionally redundant paralogue of TIMP3, was hemizygous in >50% of our discovery cohort and that having only one copy of TIMP1 increased the odds of having aortopathy (OR = 9.76, 95% CI = 1.91-178.80, p = 0.029). The combinatorial effect of a single copy of TIMP1 and TIMP3 risk alleles further increased the risk for aortopathy (OR = 12.86, 95% CI = 2.57-99.39, p = 0.004). The products of genes encoding tissue inhibitors of matrix metalloproteinases (TIMPs) are involved in development of the aortic valve and protect tissue integrity of the aorta. We propose that the combination of X chromosome TIMP1 hemizygosity and variants of its autosomal paralogue TIMP3, significantly increases the risk of aortopathy in Turner syndrome.
More Related Videos
09:39Generation of Induced Pluripotent Stem Cells from Turner Syndrome 45XO Fetal Cells for Downstream Modelling of Neurological Deficits Associated with the Syndrome
Published on: December 4, 2021
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Relative Risk
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Anatomy of the Heart
Mitral Valve Prolapse I: Introduction
Aortic Regurgitation I: Introduction