Radiographic Evaluation of Anterior Loop of Inferior Alveolar Nerve: A Cone-Beam Computer Tomography Study
Om Prakash1, Pankaj Kumar Srivastava2, Bhuvan Jyoti3
1Department of Oral and Maxillofacial Surgery and Oral Implantology, Dental Institute, RIMS, Ranchi, India.
Background:
A well awareness of the variation of inferior alveolar canal is mandatory to avoid iatrogenic complication. This study was conducted among 90 patients to determine variation in inferior alveolar nerve (IAN) loop through cone-beam computed tomography (CBCT) images.
Materials And Methods:
CBCT images of 90 patients were involved in this study. All images were studied by the expert radiologist to see Type I, Type II, and Type III pattern of IAN canal (IANC). Results were subjected to statistical analysis for correct inferences.
Results:
Forty males and 50 females were included in the study. The difference was statistically nonsignificant (P = 0.5). Type I pattern was seen in 26 patients, Type II in 19, and Type III in 45 patients. The difference was statistically significant (P < 0.05). The most prevalent pattern was Type III (males - 15 and females - 30), followed by Type I (males - 14 and females - 12) and Type II (males - 11 and females - 8). There was statistical significance difference between males and females in Type II (P < 0.05).
Conclusion:
The anterior loop of IAC is quite common and IANC may show variation in structure. The most common pattern recorded was Type III. CBCT is very useful in the detection of IANC.
More Related Videos
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Related Concept Videos
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Alveoli and Alveolar Ducts
Imaging Studies III: Computed Tomography
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Feedback Loops