Comparison of Modern Rigid Fixation Plating Outcomes for Segmental Mandibular Microvascular Reconstruction
Adam C McCann1, Yelizaveta Shnayder1, Wojciech H Przylecki2
1Department of Otolaryngology-Head and Neck Surgery, University of Kansas Medical Center, Kansas City, Kansas, U.S.A.
Objectives/Hypothesis:
New advances in osseous microvascular mandibular rigid fixation are being employed at many institutions. These include standardized prebent/preformed reconstruction plates as well as computer-aided design/computer-aided manufacturing (CAD/CAM) custom plates that are patient specific. Our goal was to assess and compare the outcomes of both of these new technologies when utilized for mandibular microvascular reconstruction.
Study Design:
Retrospective chart review.
Methods:
Subjects were categorized into two groups according to their mandibular rigid fixation technique: group 1 = prebent/preformed plates and group 2 = CAD/CAM custom plates. Primary outcome measures were 1) perioperative complications (defined as deep tissue infection, wound dehiscence resulting in bone exposure, and/or plate exposure) and 2) reoperation rates for mandibular hardware failure/explantation. Statistical analysis consisted of χ2 , Fisher exact test, and multivariable regression models.
Results:
A total of 142 subjects underwent microvascular mandibular reconstruction in a 6-year period. Eighty-nine subjects utilized prebent/preformed plates, and 53 employed CAD/CAM custom plates. Perioperative complications occurred in 32 of 89 (35.9%) subjects with prebent/preformed plates and 11 of 53 (20.7%) subjects using CAD/CAM custom plates. Reoperation requiring hardware explantation occurred in 18 of 89 (20.2%) subjects and three of 53 (5.6%) using CAD/CAM custom plates. Statistical comparison of perioperative complications between the two groups approached significance (P = .0556), and the rate of reoperation was significant favoring CAD/CAM implants (P = .0180).
Conclusions:
In our experience, CAD/CAM custom plates utilized for rigid fixation during microvascular mandibular reconstruction demonstrated fewer complications and statistically lower reoperation rates when compared with prebent/preformed plates.
Level Of Evidence:
2c Laryngoscope, 129:1081-1086, 2019.
Related Concept Videos
Modern Molecular Taxonomy
Rigid Body Equilibrium Problems - I
Predicting Reaction Outcomes
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Rigid Body Equilibrium Problems - II
Consider two children sitting on a seesaw, which has negligible mass. The first child has a mass (m1) of 26 kg and sits at point A, which is 1.6 meters (r1) from the pivot point B; the second child has a mass (m2) of 32 kg and sits at point C. How far from the pivot point B should the second child sit (r2) to balance the seesaw?
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...