Low CT temporal sampling rates result in a substantial underestimation of myocardial blood flow measurements

Marly van Assen1, Gert Jan Pelgrim1, Emmy Slager1

  • 1Center for Medical Imaging-North East Netherlands, University of Groningen, University Medical Center Groningen, EB44, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands.

Related Concept Videos

Measuring Reaction Rates03:09

Measuring Reaction Rates

Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical...
29.9K
Blood Flow01:29

Blood Flow

Blood is pumped by the heart into the aorta, the largest artery in the body, and then into increasingly smaller arteries, arterioles, and capillaries. The velocity of blood flow decreases with increased cross-sectional blood vessel area. As blood returns to the heart through venules and veins, its velocity increases. The movement of blood is encouraged by smooth muscle in the vessel walls, the movement of skeletal muscle surrounding the vessels, and one-way valves that prevent backflow.
76.0K
Autoregulation of Blood Flow01:17

Autoregulation of Blood Flow

Autoregulation mechanisms are characterized by their inherent capacity for self-regulation without necessitating specific nervous stimulation or endocrine control. These mechanisms facilitate the adjustment of blood flow and, therefore, perfusion specific to each tissue region. This self-regulation encompasses chemical signals and myogenic controls.
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
8.1K
Resultant of a General Distributed Loading01:13

Resultant of a General Distributed Loading

While designing structures exposed to non-uniform loads, it is crucial to consider the resultant force and its location. This resultant force is a single vector representing the net force applied due to the distributed load.
Examples such as load distribution due to wind and load distribution on a bridge illustrate how this concept is used to analyze and design safe, reliable structures under variable loading conditions. Most structures, such as residential buildings, bridges, and towers, are...
1.0K
Resultant Moment: Scalar Formulation01:31

Resultant Moment: Scalar Formulation

When multiple forces act on an object in two-dimensional space, the concept of the net moment can be used to understand the tendency of these forces to induce rotational motion about a fixed point. The scalar formulation of the resultant moment is a helpful tool in analyzing the equilibrium of structures subjected to multiple forces.
To determine the resultant moment, the moments caused by all the forces in a system in the x-y plane are considered. Positive moments are typically...
2.3K
Applications of Integration to Find Blood Flow01:27

Applications of Integration to Find Blood Flow

Blood flow through a cylindrical blood vessel can be mathematically described using the principles of laminar flow, a regime in which fluid moves smoothly in parallel layers. In this model, the velocity of the blood is not uniform across the cross-section of the vessel; rather, it varies with the radial distance from the center. The maximum velocity occurs along the central axis, decreasing progressively toward the vessel walls, where it reaches zero due to viscous drag.Approximating Blood...
50