A specific GC-MS method has been developed, optimized and validated for the determination of five genotoxic impurities namely Methyl bromide (Me.-Br), Ethyl bromide (Et.-Br), Isopropyl bromide (Ipr.-Br), n-Propyl bromide (n-Pr.-Br) and n-Butyl bromide (n-But.-Br) in Divalproex sodium (DPS) drug substance. Chromatographic separation of five genotoxic impurities was achieved on DB-1 column (30 m × 0.32 mm, 3.0 μm), consists of 100% dimethyl polysiloxane as stationary phase and passing helium carrier gas. The mass fragments (m/z) were selected for the quantification of Me.-Br (m/z 94), Et.-Br (m/z 108), Ipr.-Br (m/z 122), n-Pr.-Br (m/z 122) and n-But.-Br (m/z 136). Bromide ion (m/z 79) was the qualifier ion for the analytes [(Me.-Br), (Et.-Br), (Ipr.-Br), (n-Pr.-Br) and (n-But.-Br)]. The performance of the method was assessed by evaluating the specificity, linearity, sensitivity, precision and accuracy experiments. The established limit of detection and limit of quantification values for the genotoxic impurities were in the range of 0.005-0.019 μg mL-1. The correlation coefficient values of the linearity experiment were in the range of 0.9947-0.9983. The average recoveries for the accuracy were in the range of 97.6-111.3%. The results proved that the method is suitable for the determination of Me.-Br, Et.-Br, Ipr.-Br, n-Pr.-Br and n-But.-Br contents in divalproex sodium.
Related Concept Videos
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Antiepileptic Drugs: Sodium Channel Blockers
Sodium channel blockers modulate ion channels, particularly voltage-gated sodium channels. They block only sodium ion movement.
Among the most commonly prescribed antiepileptic drugs are...
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Antiarrhythmic Drugs: Class I Agents as Sodium Channel Blockers
Class 1A Antiarrhythmic Drugs: These drugs work by moderately blocking sodium channels,...
Reliability and Validity
In Vitro Drug Release Testing: Overview, Development and Validation