Related Experiment Video
Updated: Feb 4, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Covalent Organic Framework as Fiber Coating for Solid-Phase Microextraction of Chlorophenols Followed by
Tong Wu1, Xiaohuan Zang1, Mengting Wang1
1College of Science , Hebei Agricultural University , Baoding 071001 , China.
Abstract:
Headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry was adopted for the simultaneous determination of seven chlorophenols (CPs) from honey and canned-yellow-peach samples. A covalent organic framework made of 1,3,5-triformylphloroglucinol (Tp) and benzidine (BD) was used as the SPME fiber coating to preconcentrate the acetylation derivatives of the CPs. The main experimental parameters including derivatization conditions, extraction temperature and time, headspace volume, salt concentration, and desorption temperature were investigated. The fiber showed a high extraction capability for the CPs. The limits of detection (LODs) for the analytes were 0.3-0.7 μg kg-1 for honey and 0.8-1.8 μg kg-1 for canned-yellow-peach samples, suggesting good sensitivity for the method. The response linearity was 2.4-250 μg kg-1 for 2-CP and 3,4-CP and 1.0-150 μg kg-1 for the other remaining analytes in the honey samples. For the canned-yellow-peach samples, the response linearity was 6.0-300 μg kg-1 for 2-CP and 3,4-CP and 3.0-200 μg kg-1 for the others. The correlation coefficients were higher than 0.9919. Good repeatability (RSD < 11.9%) for the method and high recoveries (70.2-113%) of the analytes were observed under the optimal conditions. The established method was satisfactorily applied for the analysis of honey and canned-yellow-peach samples.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Network Covalent Solids
To break or to melt a covalent network solid, covalent bonds must be broken. Because covalent bonds are relatively strong, covalent network solids are typically...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II