Related Experiment Video
Updated: Feb 4, 2026

Purification and Analytics of a Monoclonal Antibody from Chinese Hamster Ovary Cells Using an Automated Microbioreactor System
Published on: May 1, 2019
Subunit mass analysis for monitoring multiple attributes of monoclonal antibodies
Peiran Liu1, Xin Zhu2, Wei Wu1
1Molecular and Analytical Development, Bristol-Myers Squibb, Pennington, NJ, 08534, USA.
Rationale:
Multi-Attribute Methods (MAMs) are appealing due to their ability to provide data on multiple molecular attributes from a single assay. If fully realized, such tests could reduce the number of assays required to support a product control strategy while providing equivalent or greater product understanding relative to the conventional approach. In doing so, MAMs have the potential to decrease development and manufacturing costs by reducing the number of tests in a release panel.
Methods:
In this work, we report a MAM which is based on subunit mass analysis.
Results:
The MAM assay is shown to be suitable for use as a combined method for identity testing, glycan profiling, and protein ratio determination for co-formulated monoclonal antibody (mAb) drugs. This is achieved by taking advantage of the high mass accuracy and relative quantification capabilities of intact mass analysis using quadrupole time-of-flight mass spectrometry (Q-TOF MS). Protein identification is achieved by comparing the measured masses of light chain (LC) and heavy chain (HC) mAbs against their theoretical values. Specificity is based on instrument mass accuracy. Glycan profiling and relative protein ratios are determined by the relative peak intensities of the protein HC glycoforms and LC glycoforms, respectively. Results for these relative quantifications agree well with those obtained by the conventional hydrophilic interaction liquid chromatography (HILIC) and reversed-phase LC methods.
Conclusions:
The suitability of this MAM for use in a quality control setting is demonstrated through assessment specificity for mAb identity, and accuracy, precision, linearity and robustness for glycan profiling and ratio determination. Results from this study indicate that a MAM with subunit mass analysis has the potential to replace three conventional methods widely used for mAb release testing including identification assay, glycosylation profiling, and ratio determination for co-formulated mAbs.
Related Concept Videos
Attribution Theory
Fundamental Attribution Error
Attribution
Personal Choice and Fate Attributions
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Antibody Structure
Antibodies, also known as immunoglobulins (Ig), are essential players of the adaptive immune system. These antigen-binding proteins are produced by B cells and make up 20 percent of the total blood plasma by weight. In mammals, antibodies fall into five different classes, which each elicits a different biological response upon antigen binding.
The Y-Shaped Structure of Antibodies Consists of Four Polypeptide Chains
Antibodies consist of four polypeptide chains: two identical heavy...