A comparative analysis of errors in inhaler technique among COPD versus asthma patients
Birsen Ocakli1, Ipek Ozmen1, Eylem Acartürk Tunçay1
1University of Health Sciences, Sureyyapasa Chest Diseases and Thoracic Surgery Training and Research Hospital, Istanbul, Turkey, birsenocakli@hotmail.com.
Purpose:
This study was designed to evaluate errors in inhaler technique in COPD vs asthma patients and to investigate the association of poor inhaler technique with patient demographics and clinical variables.
Patients And Methods:
A total of 509 adult patients with COPD (n=328) or asthma (n=181) who were currently using an inhaler device were included in this study. Data on patient demographics, duration of disease, type and duration of inhaler therapy, and assessment of inhaler technique were recorded.
Results:
Metered dose inhaler (MDI) was the most common type of inhaler used by a similarly high percentage of patients in both COPD (83.2%) and asthma (77.3%) groups. Failure to exhale before inhaling through device (75.8% and 68.5% for MDIs; 73.2% and 71.8% for Aerolizer®/Handihaler®; 53.1% and 66.7% for Turbuhaler®) was the most common error in inhaler technique, in both COPD and asthma groups. Device-specific errors in inhaler techniques were more common in asthma patients as compared with COPD patients, particularly for MDIs (P-values ranged from 0.046 to 0.0005), as associated with female gender (failure to press the buttons on both sides of Aerolizer®/Handihaler®, P=0.006), shorter duration of disease (failure to hold MDI or head in a vertical position, P<0.001, and to keep Turbuhaler® upright, P=0.005), and shorter duration of inhaler usage (failure to hold head in a vertical position during MDI usage, P=0.006, and to keep Turbuhaler® upright, P=0.012).
Conclusion:
In conclusion, our findings revealed that errors in inhaler technique in terms of inhalation maneuvers and device handling were similarly common in COPD and asthma patients. Errors in certain device handling maneuvers, particularly with MDIs, were more common among asthma patients than among COPD patients and associated with female gender and shorter durations of disease and inhaler therapy.
Related Concept Videos
Comparing the Survival Analysis of Two or More Groups
Inhaled Medications
Asthma-I: Introduction
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
COPD: Pathogenesis and Clinical Features
The primary cause for the onset of COPD is cigarette smoking and exposure to air pollution. These hazardous factors initiate a chain reaction within the lungs, resulting in chronic inflammation, damage to the airways, and a...
COPD: Management Using Bronchodilators and Corticosteroids